Mansions Phase 1-LR 981218 (3) Dalla$,"Forl Wodn Dallas. Texas Metro (972) 263-1555
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Galleria Villas Purchase Order
Number 3137-D7437-148 I Date of Observation 11/20/98 Report Date 12/18/98
To Genesis Real Estate Group
Contractor
Location SIDEWALK, NORTHWEST FOUNTAIN COURTYARD
Time Sampled 10:30 Time Batched 10:25 Weather Condition CLEAR
Concrete Temperature (°F) 64 Ambient Temperature (°F) 70 Mix Number GC-4050-A
Mix Description 5 SACKS, 3000 PSI Unit Weight Water Added NONE
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 6.5
ENTRAINED AIR (%) 3.4
Concrete Cylinder Test(s)
No. (Days) (lbs.) Strength (psi) Strength Required (psi)
54A 7 11/27 85000 3010 3000/28 DAYS
B 28 12/18 135000 4780
C 28 12/18 133500 4720
D H
ASTM C 31 ASTM C 39 Area 28.27 sq. in.
Signature: Mike Fuller, AET Supervisor, CMT ~{/
Remarks and/or Distribution
Distribution:
(1) Mr. Vitold Gromek; Miller-Gromek
(1) Mr. Dennis Downey; DalMac Construction
(1) Mr. John Danna, Jr.; John B. Danna, Jr., A.I.A.
(1) Mr. Dana Gregory; DalMac Construction
(3) Mr. Tom Wilder; Genesis Real Estate Group
(1) Mr. Donald Prohaska; Prohaska & Associates
LIMITATIONS: The test results presented herein were I~repared based upon the specific samples provided for testing. We assume no
responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by
persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are
addressed.
c:",wpwin;reports',D7437-148-98',ST December 18, 1998