Loading...
Mansions Phase 1-LR 981215 (3) Dadas.'Fort Worth Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 Concrete Cylinder Test Report Project Mansions By The Lake Purchase Order Number 3137-D7429-326 I Date of Observation 11/06/98 Report Date 12/15i98 To Western Rim Services Contractor Supplier LATTIMORE I P,ant 3 I Truck ~4B I T,o~et 3073324 Location PAVING, WEST APPROACH TO BUILDING #16 - 10' WEST, 5' SOUTH FROM NORTHWEST CORNER OF APPROACH Time Sampled 4:00 Time Batched 3:30 Weather Condition CLOUDY Concrete Temperature (°F) 60 Ambient Temperature (°F) 58 Mix Number 61 Mix Description Unit Weight Water Added 5 GALLONS Physical Data ACTUAL SPECIFICATIONS SLUMP (in.) 6 1/2 ENTRAINED AIR (%) 4.5 Concrete Cylinder Test(s) No. (Days) Test Date (lbs.) Strength (psi) Strength Required (psi) ~ 145A 7 11/13 ~83000 2940 · 3000/28 DAYS B 28 12/04 104000 3680 C 28 12/04 90000 3180 D H Curing Method Test Method Standard 6" x 12" Engineer/Technician J. Boster ASTM C 31 ASTM C 39 Area 28.27 sq. in. Signature: Mike Fuller, AET~.0 Supervisor, CMT Remarks and/or Distribution Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:",wpwin;reports\D7429-326-98\ST December 14, 1998