Mansions Phase 1-LR 981215 (3) Dadas.'Fort Worth Dallas. Texas Metro (972) 263-1555
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansions By The Lake Purchase Order
Number 3137-D7429-326 I Date of Observation 11/06/98 Report Date 12/15i98
To Western Rim Services
Contractor
Supplier LATTIMORE I P,ant 3 I Truck ~4B I T,o~et 3073324
Location PAVING, WEST APPROACH TO BUILDING #16 - 10' WEST, 5' SOUTH FROM NORTHWEST CORNER OF APPROACH
Time Sampled 4:00 Time Batched 3:30 Weather Condition CLOUDY
Concrete Temperature (°F) 60 Ambient Temperature (°F) 58 Mix Number 61
Mix Description Unit Weight Water Added 5 GALLONS
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 6 1/2
ENTRAINED AIR (%) 4.5
Concrete Cylinder Test(s)
No. (Days) Test Date (lbs.) Strength (psi) Strength Required (psi)
~ 145A 7 11/13 ~83000 2940 · 3000/28 DAYS
B 28 12/04 104000 3680
C 28 12/04 90000 3180
D H
Curing Method Test Method Standard 6" x 12" Engineer/Technician J. Boster
ASTM C 31 ASTM C 39 Area 28.27 sq. in.
Signature: Mike Fuller, AET~.0 Supervisor, CMT
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Mike Hodge; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no
responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by
persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are
addressed.
c:",wpwin;reports\D7429-326-98\ST December 14, 1998