Mansions Phase 1-LR 981214 (4) :! Dallas.-'Fort Worl:h i Da~as. Texas Metro (972)263-15,~ ~~ 75229 Fax (972) 241-5174 Concrete Cylinder Test Report Project Mansions By The Lake Purchase Order Number 3137-D7429-291 I Date of Observation 10/16/98 Report Date 12/14,/98 To Western Rim Services Contractor Location SLAB ON GRADE, BUILDING //33 - 30' EAST, 20' SOUTH FROM NORTHWEST CORNER OF BUILDING Time Sampled 9:00 Time Batched N/A Weather Condition CLOUDY Concrete Temperature (°F) 77 Ambient Temperature (°F) 74 Mix Number 51 Mix Description Unit Weight Water Added 5 GALLONS Physical Data ACTUAL SPECIFICATIONS SLUMP (in.) 5 1/2 Concrete Cylinder Test(s) Specimen I Age I Test Date l TOtal Load l Compressive No. (Days) (lbs.) Strength (psi) Strength Required (psi) 128A 7 10/23 68000 2410 3000/28 DAYS B 28 11/13 83000 2940 C 28 11/13 84000 2970 D 56 12/11 96500 3410 I I Curing Method Test Method I Standard 6" x 12" I Engineer/Technician R. LOVELADY Area 28.27 sq in. ASTM C 31 ASTM C 39~ I · I Signature: Mike Fuller, AET~i~ Supervisor, CMT Remarks and/or Distribution~.~. Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr, Mike Hodge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C, D. Construction Consulting LIMITATIONS: The test results presented herein were prel3ared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.} or any other feature of similar subject matter provided bv persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. cCwpwin\reports',D7429-291-98\ST December 14, 1998