Mansions Phase 1-LR 981214 (4) :! Dallas.-'Fort Worl:h i Da~as. Texas Metro (972)263-15,~ ~~
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansions By The Lake Purchase Order
Number 3137-D7429-291 I Date of Observation 10/16/98 Report Date 12/14,/98
To Western Rim Services
Contractor
Location SLAB ON GRADE, BUILDING //33 - 30' EAST, 20' SOUTH FROM NORTHWEST CORNER OF BUILDING
Time Sampled 9:00 Time Batched N/A Weather Condition CLOUDY
Concrete Temperature (°F) 77 Ambient Temperature (°F) 74 Mix Number 51
Mix Description Unit Weight Water Added 5 GALLONS
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 5 1/2
Concrete Cylinder Test(s)
Specimen I Age I Test Date l TOtal Load l Compressive
No. (Days) (lbs.) Strength (psi) Strength Required (psi)
128A 7 10/23 68000 2410 3000/28 DAYS
B 28 11/13 83000 2940
C 28 11/13 84000 2970
D 56 12/11 96500 3410
I
I
Curing Method Test Method I Standard 6" x 12" I Engineer/Technician R. LOVELADY
Area 28.27 sq in.
ASTM C 31 ASTM C 39~ I ·
I
Signature: Mike Fuller, AET~i~ Supervisor, CMT
Remarks and/or Distribution~.~.
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr, Mike Hodge; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C, D. Construction Consulting
LIMITATIONS: The test results presented herein were prel3ared based upon the specific samples provided for testing. We assume no
responsibility for variation in quality (composition, appearance, performance, etc.} or any other feature of similar subject matter provided bv
persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are
addressed.
cCwpwin\reports',D7429-291-98\ST December 14, 1998