Loading...
Mansions Phase 1-LR 981207 Da:las. Forl '¢./o'I,n Dallas. Texas Metro ."Q7P', pRq_l 75229 Fax (972) 241-5174 Concrete Cylinder Test Report Project Mansions By The Lake Purchase Order Number 3137-D7429-339 I Date of Observation 11/24/98 Report Date 12/07/98 To Western Rim Services Contractor Supplier LATTIMORE I Plant 6 I Truck 617 I Ticket 6085164 Location PAVING - 15' NORTH, 15' WEST FROM NORTHWEST CORNER OF BUILDING #15 Time Sampled 9:15 Time Batched 8:28 Weather Condition CLOUDY Concrete Temperature (~"F) 69 Ambient Temperature (°F) 64 Mix Number 61 Mix Description Unit Weight Water Added NONE Physical Data ACTUAL SPECIFICATIONS SLUMP (in.) 5 1/2 ENTRAINED AIR (%) 3.6 Concrete Cylinder Test(s) Specimen Age Test Date No. (Days) (lbs.) Strength (psi) Strength Required (psi) 1 52A 7 1 2/01 77000 2720 3000/28 DAYS B 28 12/22 C 28 1 2/22 D H Curing Method I Test Method Standard 6" x 12" I Engineer/Technician R. LOVELADY ASTM C 31 I ASTM C 39 Area 28.27 sq. in. I Signature: Mike Fuller, AE Supervisor, CMT Remarks and/or Distribution~,,~ Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting L;MITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and ,eports are for the exclusive use of the clients to whom they are addressed. c::wpwin:reports'.D7429-339-98'.ST Decem,"er 7, 1998