Loading...
Mansions Phase 1-LR 981123 Dallas Fort Wc.d.'~ Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansions By The Lake Page I of 4 Report No: 3137-D7429-335 Sample Date: November 18, 1998 Client: Western Rim Services Report Date: November 23, 1998 I.ocation: Builidng #15 Technician: R. Lovelady ~ Tendon Location Jack Force Gauge Required Elongations Elongations Total Within No. ('Kips) Pressure Elongations End (1) End (2) Elongations Tolerance 1 S-59 N Side - E to W 33K 55.00 4 5/8 4 1/2 YES 2 B-59 N Side - E to W 33K 5500 4 5/8 4 1/2 YES 3 S-68 N Side - E to W 33K 5500 5 3;8 5 1/2 YES 4 S-96 N Side - E to W 33K 5500 7 1/2 7 3/8 YES 5 S-98.6 N Side - E to W 33K 5500 7 3/4 8 1/4 YES 6 S-98.6 N Side - E to W 33K 5500 7 3/4 7 1/4 YES 7 B-73.6 N Side - E to W 33K 5500 5 5!8 5 1!2 YES 8 S-100 N Side - E to W 33K 5500 7 7/8 7 314 YES 9 S-100 N Side - E to W 33K 5500 7 7/8 8 YES 10 S-l(}0 N Side - E to W 33K 5500 7 718 7 7/8 YES 11 B-73 N Side - E to W 33K 5500 5 5:8 5 1i'2 YES 12 S-96 N Side - E to W 33K 5500 7 1/2 7 3/4 YES 13 S-96 N Side - E to W 33K 5500 7 1/2 7 3i4 YES 14 S-96 N Side - E to W 33K 5500 7 1/2 7 3/4 YES 15 S-96 N Side - E to W 33K 5500 7 1/2 7 1.14 YES 16 S-98.6 N Side - E to W 33K 5500 7 3;4 7 5/8 YES 17 B-71.6 N Side - E to W 33K 5500 5 1/2 5 1/2 YES 18 S-98.6 N Side - E to W 33K 5500 7 3/4 7 1/4 YES 19 S-98.6 N Side - E to W 33K 5500 7 3/4 8 YES Equipment ID: Ram No: 93014 Pump No: 381996 Gauge No: 93014 Equipment Calibration Date: 9/04/98 Comments: Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Nlr. Mike Hodge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMI'rATIONS: The test resutts presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or an)' other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom the}' are /txI addressed. c:\wpwin'~reports,,D7429-335.98~.ST November 23, 1998 Rone Encjineers, Inc. ~ "'~34 Goodnight L~ne ! Tel. (~72) 241-45~-- RoneEnqineers Da,as-'Fort Wor[h Dallas, Texas = Metro (972) 263-1555 75229 i Fax (972) 241-5174 ELONGATION REPORT Project: Mansions By The Lake Page 2 of 4 Report No: 3137-D7429-335 Sample Date: November 18, 1998 Client: Western Rim Services Report Date: November 23, 1998 Location: Builidng #1S Technician: R. Lovelady ~ Tendon Location Jack Force Gauge Required Elongations Elongations Total Within No. (Kips) Pressure Elongations End (l } End (2) Elongations Tolerance 20 S-98.6 N Side - E to W 33K 5500 7 3/4 7 5!8 YES 21 B-76 N Side - E to W 33K 5500 6 5 3/4 YES 22 S-12,6 N Side - E to W 33K 5500 718 3/4 YES 23 S-26 N Side - E to W 33K 5500 2 1 7/8 YES 24 S-26 S Side - W to E 33K 5500 2 1 7!8 YES 25 S-26 S Side - W to E 33K 5500 2 1 7/8 YES 26 B-27 S Side - W to E 33K 5500 2 1/8 I 15/16 YES 27 S-27 S Side - W to E 33K 5500 2 1/8 I 15/16 YES 28 S-46 S Side - W to E 33K 5500 3 5/8 3 3/4 YES" 29 B-27 S Side - W to E 33K 5500 2 1:'8 2 1i8 YES 30 B-27 S Side - W to E 33K 5500 2 1/8 2 I/4 YES" 31 B-27 S Side - W to E 33K 5500 2 1/8 2 1/8 YES 32 B-27 S Side - W to E 33K 5500 2 1/8 2 1/8 YES 33 S-55 S Side - W to E 33K 5500 4 4 1/8 YES 34 B-55 S Side - W to E 33K 5500 4 1/4 4 1/4 YES 35 B-65.5 S Side - W to E 33K 5500 5 1/8 5 3/8 YES 36 S-60.6 E Side - S to N 33K 3500 4 3!4 4 5/8 YES 37 S-59.6 E Side - S to N 33K 5500 4 518 4 5/8 YES 38 S-59.6 E Side - S to N 33K 5500 4 5/8 4 5/8 YES Equipment ID: Ram No: 93014 Pump No: 381996 Gauge No: 930214 Equipment Calibration Date: 9/04/98 Comax~ents: * No. 28, S-46- covered up, repuiled 11/19; No. 30, B-27- pulled loose, repulled 11/19. Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject maner provided by persons or conditiotts over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:\'~,,pwin',reports:D7429-335-98',ST November 23, 1998 rto,-,~ ¢,-,~ .... ~, t,-,¢. , --,~4 Qood,-,tght {_~ne To(. (~72i 241-45~-' RoneEnqineers Dallas 'roq Worth Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansions By The Lake Page 3 of 4 Report No: 3137-D7429-335 Sample Date: November 18, 1998 Client: Western Rim Services Report Date: November 23, 1998 Location: Builidng/915 Technician: R. Lovelady Jack Force Gauge Required [ Elongations Elongations Total Wilhin Tendon Location No. (Kips) Pressure Elongations End (I) End (2} Elongations Tolerance 39 B-59.6 E Side - S to N 33K 5500 4 5;8 4 1/2 YES 40 S-59.6 E Side - S to N 33K 5500 4 5/8 4 1/2 YES 41 S-62.6 E Side ~ S to N 33K 5500 4 7/8 5 1:8 YES 42 S-62.9 E Side - S to N 33K 5500 4 7/8 4 5/8 YES 43 B-62.9 E Side - S to N 33K 5500 4 7;8 4 3/4 YES 44 S-59 E Side - S to N 33K 5500 4 5;8 4 1/2 YES 45 S-59 E Side - S to N 33K 5500 4 5/8 4 1/2 YES 46 S-61.6 E Side - S to N 33K 5500 4 3/4 4 5/8 YES 47 B-61.6 E Side - S to N 33K 5500 4 3/4 4 5/8 YES 48 S-61.6 E Side - S to N 33K 550{} 4 3/4 4 5i8 YES 49 S-59.6 E Side - S to N 33K 550{} 4 5.."8 4 3/4 YES 5{} S-61.6 E Side - S to N 33K 5500 4 3/4 4 5.~8 YES 51 S-61.6 E Side - S to N 33K 5500 4 3/4 4 5/8 YES 52 S-59.6 E Side - S to N 33K 5500 4 5/8 4 314 YES 53 S-59.6 E Side - S to N 33K 5500 4 5/8 4 1i2 YES 54 S-67 E Side - S to N 33K 5500 5 1/4 5 1/2 YES 55 B-67 E Side - S to N 33K 5500 5 1/4 5 3/8 YES 56 S-67 E Side - S to N 33K 5500 5 1/4 5 YES 57 S-67 E Side - S to N 33K 5500 5 !14 5 1/4 YES Equipment ID: Rain No: 93014 Pump No: 381996 Gauge No: 93014 Equipment Calibration Date: 9/04/98 Comments: Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to who~n they are addressed. c:',wpwin~.reports~.D7429-335-98'~ST November 23, 1998 Da,~as-Foq Wont, ' Dallas, Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansions By The Lake Page 4 of 4 Report No: 3137-D7429-335 Sample Date: November 18, 1998 Client: Western Rim Services Report Date: November 23, 1998 Location: Builidng #15 Technician: R. Lovelady # Tendon Location Jack Force Gauge Required Elongatir, ns [ EIo~,gations Total Within No. (Kips') Pressure Elongations End ( I ) End f2) Elongations Tolerance 58 S-67 E Side - S to N 33K 5500 5 1:4 5 1/4 YES 59 B-67 E Side - S to N 33K 5500 5 1/4 5 1/4 YES 60 S-67 E Side - S to N 33K 5500 5 1/4 5 9/16 YES 61 S-67 E Side - S to N 33K 5500 5 1!4 5 1!2 YES 62 S-59 E Side - S to N 33K 5500 4 5/8 4 1/2 YES 63 S-29.6 E Side - S to N 33K 5500 2 114 2 I/8 YES 64 B-29.6 E Side - S to N 33K 5500 2 1,.'4 2 3/16 YES Equipment ID: Ram No: 93014 Pump No: 381996 Gauge No: 93014 Equipment Calibration Date: 9/04/98 Conunents: Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test resuhs presented herein were prepared based upon the specific samples provided for testing· We assume no respozbibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject mal~er provided by persoits or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:'wvpwin',.reports',D7429-335-98\ST November 23, 1998