Loading...
Mansions Phase 1-LR 981123 (2) -2.al as re,: ',V::.r:'- Dallas. Texas Metro (972) 263-15,55 75229 Fax (e, 72i 241-517,; ELONGATION REPORT Project: Mansions Bv The Lake Page 1 of 4 Report No: ola,-D7429-.~o6 Sarnple Date: November 18, 19, 1998 Client: Western Rim Services Report Date: November 23, 1998 Location: Building//15 Technician: R. Lovelady # Tendal] Locatia,~ Jack Force Gauge Required Elongauons Elongations Total W~thin No. ~ Kips) Pressure Elongations End t 1 ) End t'2~ Elongations Tolerauce 1 S-59 N Side - E ~.,) W 33K 5500 4 5:8 4 !;2 YES 2 B-59 N Side - E to W 33K 5500 4 5:8 4 1:2 YES '~ S-68 N Stde- E to W 33K 5500 5 3:8 5 1:2 YES 4 S-96 N Side - E to W 33K 5500 7 1:2 7 1:2 YES 5 S 98.6 N Side - E to W 33K 5500 7 3/4 7 '7.:8 YES 6 5-98.6 N Side - E to W 33K 5500 7 3:4 ? 1:4 YES 7 B-73 O N Side E [o W 33K 5500 5 5:8 5 1:2 5.'ES 8 S-lbo N S:3e E to W 33K 5500 7 7;8 '7.' 1:2 YES 9 S-100 N Side E to W 33K 5500 7 7;8 8 YES 10 S-lO0 N Side E to W 33K 5500 7 7:8 7 3'8 YES 1! B-73 N Side I! to W 33K 5500 5 5:8 5 1:4 YES 12 S-96 N S~tle E to W 33K 5500 7 1 2 7 3:8 5.'ES 13 S-96 N S~de - E to W 33K 5500 7 1-2 ? !:2 5.'ES 1-1 S-9'6 N S,'de - 15 to W 33K 5500 7 1:2 '7. 3:8 YI".S 15 S-96 N Side - E to W 33K 5500 7 1:2 7 1/2 5.-ES 16 S-98.6 N Side - E to W 33K 5500 7 3:4 7 Ii2 5.'ES 17 B-71.6 N S~3c - E to W 33K 5500 5 1 '2 5 5.'8 5.'ES 18 S-98.6 N S~de - E to W 33K 5500 7 3 4 7 1:4 YES 19 S-98.6 N Skit - E to W 33K 5500 7 3:4 '7 1.'4 YES Equipment ID: P, am No: 93014 Pump No: 381996 Gauge No: 93014 Equipment Calibration Date: 9/04;98 Comments: No. 15, S-96 - cable slipped back, repulled 11/19. Distribution: (1) Mr. Richard E. Simmons; Western Rim Services 1,1) Mr. Larry Davis; City of Coppell (1) Mr. Ylike Hodgc; City of Coppell (,11 Mr. Tony Martin; Newport Classic 1'1) Mr. Doyle Damron; C. D. Construction Consulting LIMI]'ATiONS: The test results presented herein 'acre prepared based upc ~ the specific sample~ provided for testing, x,\'e assume no responsibility lbr variation in quality (composition, al)pear,race, pertbrmance, etc.) or an> other feature of similar subject matter pro\ idcd k":' persons or conditions uver v. hich we have no control. Our letters and reports are for the exclusive use of the clients IO whom they are addressed. c:'.wp',~in-.rcForts'.D7429-336-98ST Noxcnfl~r 23, 1998 ~ '" f~ ,',9721: Ca.~-: ¢::r~:: v,'-.:",'~ ; Dallas. Texas :..,,et:u 263-1555 75229 ;ax :a77'~ 241-5174 ELONGATION REI'ORT Project: Mansions By The Lake Page 2 of 4 Report No: 3137-D7429-336 Sample Date: November 18, 19, 1998 Client: Western Rim Services Report Date: November 23, 1998 Location: Building//15 Technician: R. Lovelady # Tendon [.o,:ation Jack Force Gauge Required Elongations Elongations Total \Vithm Nc.. ~Kips'} Pressure Elongations Y_nd ~11 End ~2:. Elongations Tolerance 2(I S-98.6 N S:Jc - E to W 33K 5500 7 3.'.1- '7 1.'4 YES 2! B-76 N S;,l,: - E ~o W 33K 5500 6 "5:8 YF_S 22 S-!2.6 N Sid~ - E to W 33K 5500 7.'8 7.'8 YES 23 S-26 N S;de - E to W 33K 5500 2 1 15:16 YES 24 S-26 N S~de * E to W 33K 5500 2 2 YES 25 S-26 N Side - E to W 33K 55(0 2 I 15-'16 YES 26 11-27 S Side - W to E 33K 5500 2 1.'8 1 15.-'16 YI/S 27 S-27 S Side - W to E 33K 5500 2 1;8 2 YI£S 28 S-46 S Side - W to E 33K 5500 3 5.'8 3 1.'2 YES 29 B-27 S Side - W to E 33K 5500 2 1.'8 2 YES 30 B-27 S Si(lc - W to E 33K 5500 2 1:8 2 1:8 YES 31 B-27 S Sklc - W to E 33K 5500 2 1-'8 2 YES 32 B 27 S Side - W to E 33K 5500 2 1-'8 2 YES 33 SI 55 S Si,lc - W to F 33K 55(>0 4 1-'4 -I 5'I:.5 34 B-55 S Side - ~,x,- to E 33K 5500 4 1;4 4 YES 35 B-65.5 S Side - W to E 33K 5500 5 I.-'8 5 I 'S YES 36 S-60.6 E Side - S to N 33K 5500 4 3.-'4 4 5.-'8 YES 37 S-59.6 E Si3e - S to N 33K 55~-} 4 5:8 4 1:2 YES 38 S-59.6 E Side - S to N 33K 5500 4 5-'8 4 5.-8 YES Equipment ID: Ram No: 93014 Pump No: 381996 Gauge No: 93014 Equipment Calibration Date: 9..'04..'98 Colnmcnts: No. 15, S-96 - cable slipped back, repullcd 11/19. Distribution: (1) Mr. Richard E. SinlnlOllS; Western Rim Services (11 Mr. I.arry Davis: City of Coppell ('1) .Mr. Mike tlodge; City of Coppell !11 Mr. Tony Martin; Newport Classic ( 1.1 Mr. Doyle Damron; C. D. Constructkm Consulting [.IMITATIONS: Tire test results presented herein were prepared based upon the specific sample~ provided for testing. \Ve a,,sumc no re3poos~bility for variation Jo quality ~cumposidon, appearance, l)erformance, etc.) or any other feature of sim.'lar subject matter F-.rovidcd by i:er~ons or conditions over v,]:i~;[l we have na conlrol. Our letters and report.s are for tire exclusive use of file clients to who. n: riley arc addressed. c: v,?win repons',D7429-336-98,ST Novelnber 23. 1998 D.:- .~s Fy"'. '¢,c-"..~ Dallas. Texas Metro (972) 263-i 555 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansions By The Lake Page 3 of 4 Report No: 3137-D7429-336 Sample Date: November 18, 19, 1998 Client: Western Rim Services Report Date: November 23, 1998 Location: Building//15 Technician: R. Lovelady # Tendon Location lack Force Gauge Required Elongations Etongations Total Within No. (Kips) Pressure Elongations End (1) End (2) Elongations 'rcleranze 39 B-59.6 E Side - S to N 33K 5500 4 5;8 4 1;2 YES 40 S-59.6 E Side - S to N 33K 5500 4 5:8 4 9:16 YES 41 S-62.6 E Side - S to N 33K 5500 4 7;8 5 1:8 YES 42 S-62.9 E Side - S to N 33K 5500 4 7;8 5 YES 43 B-62.9 E S:de - S to N 33K 5500 4 7;8 4 7.'8 YES 44 S-59 E Side - S to N 33K 5500 4 5.'8 4 5;8 YES 45 S-59 E Side - S to N 33K 5500 4 5:8 4 7:8 YES 46 S-61.6 E Side - S to N 33K 5500 4 3J4 4 5/8 YES 47 B-61.6 E Side - S to N 33K 5500 4 3/4 5 YES 48 S-61.6 E Side - S to N 33K 5500 4 3;4 5 YES 49 S-59.6 E Side - S to N 33K 5500 4 5.;8 4 3:4 YES 50 S-61.6 E Side - S m N 33K 5500 4 3!4 5 YES 51 S-6!.6 E Side - S to N 33K 5500 4 3i4 5 I.-'16 YES 52 S-59.6 E Side - S to N 33K 5500 4 5/8 4 7:8 YES 53 S-59.6 E Side - S m N 33K 5500 4 5."8 4 3.'4 YES 54 S-67 E Side - S to N 33K 5500 5 1;4 5 1,'8 YES 55 B-67 E Side - S to N 33K 5500 5 1/4 5 3:16 YES 56 S-67 E Side - S to N 33K 5500 5 1i4 5 3:8 YES 57 S-67 E Side - S to N 33K 55tko 5 1.'4 5 1;8 YES Equipment ID: Ram No: 93014 Pump No: 381996 Gauge No: 93014 Equipment Calibration Date: 9,."04/98 Comments: No. 15, S-96 - cable slipped back, repulled 11/19. Distribution: (1) Mr. Richard E. Simmons: Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppeil (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upou the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearauce, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clien[s to whom the3 are addressed. c:'wpwin".reports:D7429-336-98xST November 23, 1998 D~ a.-,: r.,;.c .:.,-'::,:~,.-. Dallas, Texas Metro (972) 263-1555 75229 Fax ~'972:241-5174 ELONGATION REPORT Project: Mansions By The Lake Page 4 of 4 Report No: 3137-D7429-336 Sample Date: November 18, 19, 1998 Client: Western Rim Services Report Date: November 23, 1998 Location: Building//15 Technician: R. Lovelady # Tendon Location Jack Force Gauge Required Elongations Elongations Total Widfin No. (Kips ~ Pressure Elongations End f 1 ) End (2) Elongations Toleranze 58 S-67 E Side - S to N 33K 5500 5 1;4 5 YES 59 B-67 I?. Side - S to N 33K 5500 5 1;4 5 1:8 YES 60 S-67 E Side - S to N 33K 5500 5 1/4 4 15..'16 YES 61 S-67 E Side - S to N 33K 5500 5 1.'4 4 15.:16 YES 62 S-59 E Side - S to N 33K 5500 4 5i8 4 I;2 YES 63 S-29.6 E .Side - S to N 33K 5500 2 1i4 2 1/4 YES 64 B-29.6 E Side - S to N 33K 55(X) 2 1/4 2 1/8 YES Equipment ID: Ram No: 93014 Pump No: 381996 Gauge No: 93014 Equipment Calibration Date: 9/04/98 Comments: No. 15, S-96 - cable slipped back, repulled 11/19. Distribution: (1) Mr. Ricb. ard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppcll (l) Mr. ]'on3' Martin; Newport Classic LIMITATIONS: The test results presented herein ,.,.ere prepared based upon tile specific samples provided for testing. We assume no respoe, sibility for variation in quality (composition, appearance, performance, etc.) or any other lean,re of similar subject matter provided by persons or couditk)ns over which we ha~,-e no control. Our letters and relx)rts are for the exclusive use of the clients to whom fl~ey are addressed. c::wpwin".rel)orts'.D7429-336-98:ST November 23. 1998