Mansions Phase 1-LR 981119 (7) pa~las.-'r'ort '¢;c.~ i Dallas. Texas Metro (972) 263-1555
' 75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansions By The Lake Purchase Order
Number 3137-D7429-298 I Date of Observation 10/22/98 Report Date 11/19/98
To Western Rim Services
Contractor
Location PAVING - 75" NORTHEAST, 25' SOUTHWEST FROM NORTH CORNER OF BUILDING
Time Sampled 12:55 Time Batched 12:16 Weather Condition PT CLOUDY
Concrete Temperature (°F) 70 Ambient Temperature (°F) 60 Mix Number 61
Mix Description Unit Weight Water Added NONE
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 5 1/2
ENTRAINED AIR (%) 4.0
Concrete Cylinder Test(s)
No. (Days) (lbs.) Strength (psi) Strength Required (psi)
1 30A 7 10/29 83000 2940 3000/28 DAYS
B 28 11/19 105000 3710
C 28 11/19 112000 3960
D H
I
Curing Method I Test Method I Standard 6" x 12" I Engineer/Technician S. SPARKMAN
ASTM C 31I ASTM C 39 .[ Area 28.27 sq. in.
I
Signature: Mike Fuller, AET t~Supervisor, CMT
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Mike Hedge; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no
responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by
persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are
addressed.
c:\wpwin',reports'.D7429-298-98\ST November 19, 1998