Mansions Phase 1-LR 981116 (4) n~n~ 12~gi,~r~. I~e. 11_224 Goodmght LArge Tel. (§72) 24 !-4517-, RoneEnqineers
3al:as.'For:. wo~' Da.as. Texas Metro (972) 263-15o5
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansions By The Lake Purchase Order
Number 3137-D7429-322 J Date of Observation 11/05/98 Report Date 11/16/98
To Western Rim Services
Contractor
Supplier LATTIMORE I Plant 6 I Truck 805 I Ticket 6084000
Location PAVING, APPROACH ON WEST SIDE OF BUILDING #32 - 20' SOUTH, 15' WEST FROM NORTHWEST CORNER OF
BUILDING
Time Sampled 11:00 Time Batched 9:45 Weather Condition PT CLOUDY
Concrete Temperature (°F) 62 Ambient Temperature (°F) 49 Mix Number 61
Mix Description Unit Weight Water Added 10 GALLONS
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 4 1/2
ENTRAINED AIR (%) 3,1
Concrete Cylinder Test(s)
No. (Days) (lbs.) Strength (psi) Strength Required (psi)
143A 7 11/12 89000 3150 3000/28 DAYS
B 28 12/03
C 28 12/03
D H
Curing Method I TestMethod I Standard 6" x12" I Engineer/TechnicianR. LOVELADY
ASTM C 31 ASTM C 39/,,J Area 28.27 sq. in.
Signature: Mike Fuller, AET /Supervisor, CMT
Remarks and/or Distribution "~
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Mike Hodge; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no
responsibdity for variation ~n quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by
persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are
addressed.
c:'.wpwimreports',D7429-322-98\ST November 16, 1998