Loading...
Mansions Phase 1-LR 981116 (4) n~n~ 12~gi,~r~. I~e. 11_224 Goodmght LArge Tel. (§72) 24 !-4517-, RoneEnqineers 3al:as.'For:. wo~' Da.as. Texas Metro (972) 263-15o5 75229 Fax (972) 241-5174 Concrete Cylinder Test Report Project Mansions By The Lake Purchase Order Number 3137-D7429-322 J Date of Observation 11/05/98 Report Date 11/16/98 To Western Rim Services Contractor Supplier LATTIMORE I Plant 6 I Truck 805 I Ticket 6084000 Location PAVING, APPROACH ON WEST SIDE OF BUILDING #32 - 20' SOUTH, 15' WEST FROM NORTHWEST CORNER OF BUILDING Time Sampled 11:00 Time Batched 9:45 Weather Condition PT CLOUDY Concrete Temperature (°F) 62 Ambient Temperature (°F) 49 Mix Number 61 Mix Description Unit Weight Water Added 10 GALLONS Physical Data ACTUAL SPECIFICATIONS SLUMP (in.) 4 1/2 ENTRAINED AIR (%) 3,1 Concrete Cylinder Test(s) No. (Days) (lbs.) Strength (psi) Strength Required (psi) 143A 7 11/12 89000 3150 3000/28 DAYS B 28 12/03 C 28 12/03 D H Curing Method I TestMethod I Standard 6" x12" I Engineer/TechnicianR. LOVELADY ASTM C 31 ASTM C 39/,,J Area 28.27 sq. in. Signature: Mike Fuller, AET /Supervisor, CMT Remarks and/or Distribution "~ Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibdity for variation ~n quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:'.wpwimreports',D7429-322-98\ST November 16, 1998