Mansions Phase 1-LR 981113 (2) ne,~ E~§i.~.~. I,e. ~ t~-.94 Goodmght Lane TeL (972) 241-451% RoneEngineers
Dal,as. For:. Wcdh Da,as. Texas Metro (972) 263-1565
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansions By The Lake Purchase Order
Number 3137-D7429-285 I Date of Observation 10/14/98 Report Date 11/13/98
To Western Rim Services
Contractor
Supp,er TTIMORE I Plant 6 I Tr.ck 939 I Ticket 6082378
Location BUILDING PAD #15 - 30' SOUTH, 15' WEST FROM NORTHEAST CORNER OF BUILDING PAD
Time Sampled 8:30 Time Bitched 8:00 Weather Condition PT CLOUDY
Concrete Temperature (°F) 77 Ambient Temperature (°F) 64 Mix Number 51
Mix Description Unit Weight Water Added 15 GALLONS
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 5.0
Concrete Cylinder Test(s)
No. (Days) (lbs.) Strength (psi) Strength Required (psi)
124A 7 10/21 67000 2370 3000/28 DAYS
B 28 11/11 95000 3360
C 28 11/11 98000 3470
D H
Curing Method Test Method I Standard 6" x 12"
I
Engineer/Technician
R.
LOVELADY
ASTM C 31 ASTM C 39 ~, Area 28.27 sq. in. I
Signature: Mike Fuller, AET ~!Supervisor, CMT
Remarks and/or Distribution~1¢~,_
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Mike Hodge; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no
responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by
persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are
addressed.
c:\wpwimreports\D7429-285-98\ST November 13, 1998