Mansions Phase 1-LR 981110 noll~ P.-nyin~t~r,~, Inc;. I ....... ~4 r~oo~rllghl Lane 'Tel.
Dallas?od Wor',n Dallas. Texas Metro (972) 263-1555
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansions By The Lake Purchase Order
Number 3137-D7429-305 [ Date of Observation 10/26/98 Report Date 11/10!98
To Western Rim Services
Contractor
Supplier LATTIMORE I Plant 7 J Truck 944 Ticket 7060550
Location PAVING - 25' NORTH, 20' EAST OF SOUTHEAST CORNER OF BUILDING #18
Time Sampled 1:00 Time Batched 11:41 Weather Condition PT CLOUDY
Concrete Temperature (°F) 76 Ambient Temperature (°F) 78 Mix Number 61
Mix Description Unit Weight Water Added 10 GALLONS
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 4 1/2
ENTRAINED AIR (%) 3.3
Concrete Cylinder Test(s)
No. (Days) (lbs.) Strength (psi) Strength Required (psi)
1 34A 7 11/02 73000 2580 3000/28 DAYS
B 28 11/23 94000 3330
C 28 11/23 92000 3250
D H
Curing Method I Test Method I Standard 6" x 12" Engineer/Technician R. LOVELADY
ASTM C 31 I ASTM C 39 )-~Area 28.27 sq. in.
Signature: Mike Fuller, AET /~'~Supervisor, CMT
Remarks and/or Distribution ~
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Mike Hodge; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no
responsibility for variation in quality {composition, appearance, performance, etc.) or any other feature of similar subject matter provided by
persons or conditions over whlch we have no control. Our letters and reports are for the exclusive use of the clients to whom they are
addressed.
c:"""pwin~-reports'.D7429-305-98',ST November 10, 1998