Mansions Phase 1-LR 981109 (3) ~&~4 E.~Ji~4e~e, I.e. ~ ~_~zZ C~d~ight L2.n,~ .. TeL (972) 241-4517-- RoneEnqineers
DaHas,"Foc, Worth Da.as. Texas Metro (972) 263-15~
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansions By The Lake Purchase Order
Number 3137-D7429-301 I Date of Observation 10/23/98 Report Date 11/09/98
To Western Rim Services
Contractor
Location PAVING - 10' SOUTH AND 10' EAST OFF NORTHEAST CORNER OF BUILDING PAD//23
Time Sampled 9:35 Time Bitched 7:46 Weather Condition PT CLOUDY
Concrete Temperature (°F) 74 Ambient Temperature (°F) 60 Mix Number 61
Mix Description Unit Weight Water Added 10 GALLONS
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 5 1/2
Concrete Cylinder Test(s)
No. (Days) Test Date (lbs.)_ Strength (psi) Strength Required (psi)
132A 7 10/30 64000 2260 3000/28 DAYS
B 28 11/20
C 28 11/20
D H
Curing Method Test Method Standard 6" x 12" Engineer/Technician K. MUSTAFA
ASTM C 31 ASTM C 39 Area 28.27 sq. in.
Signature: Mike Fuller, AET Supervisor, CMT,~,%~
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Mike Hodge; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no
resl~onsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by
persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are
addressed.
c:',wpwin\reports\D7429-301-98\ST November 9, 1998