Mansions Phase 1-LR 981106 112_~z~ Gdddnight L~n~ Tet. (972) 241-4517 -- RoneEngineers
Dallas. Texas Metro (972) 263-155~
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansions By The Lake Purchase Order
Number 3137-D7429-297 I Date of Observation 10/22/98 Report Date 11/06/98
To Western Rim Services
Contractor
Supplier LATTIMORE Plant 6 I Truck 753 I Ticket 6082889
Location PAVING - 15' NORTHEAST, 20' SOUTHWEST FROM NORTH CORNER OF BUILDING #20
Time Sampled 9:36 Time Batched 8:52 Weather Condition PT CLOUDY
Concrete Temperature {°F) 63 Ambient Temperature {°F) 84 Mix Number 61
Mix Description Unit Weight Water Added NONE
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 8.0
ENTRAINED AIR (%) 3.2
Concrete Cylinder Test(s)
SpecimenI Age I Test Date I Total Load I Compressive
No. (Davs) (lbs.) Strength (psi) Strength Required (psi)
1 29A 7 10/29 70000 2480 3000/28 DAYS
B 28 11/19
C 28 11/19
D H
I
I
Curing Method I Test Method I Standard 6" x 12" Engineer/Technician S. SPARKMAN
ASTM C31I ASTM C39I Area 28.27 sq. in.
Signature: Mike Fuller, AET [~,) Supervisor, CMT
Remarks and/or Distribution
Project Superintendent was informed of slump.
Distribution: (1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Mike Hodge; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no
responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by
persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are
addressed.
c:\wpwin'.reports~D7429-297-98\ST November ~, 1998