Loading...
Mansions Phase 1-LR 981030 (5) ". RoneEnaineers Da~=as. Fc,~ Wo~ Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 Concrete Cylinder Test Report Project Mansions By The Lake Purchase Order Number 3137-D7429-271 I Date of Observation 10/01/98 Report Date 10/30/98 To Western Rim Services Contractor Location SLAB ON GRADE, BUILDING //3 - 30' WEST, 10' SOUTH FROM NORTHEAST OF BUILDING Time Sampled 8:50 Time Batched 8:30 Weather Condition PT CLOUDY Concrete Temperature (°F) 83 Ambient Temperature (°F) 79 Mix Number 51 Mix Description Unit Weight Water Added NONE Physical Data ACTUAL SPECIFICATIONS SLUMP (in.) 5 1/2 Concrete Cylinder Test(s) Specimen r AgeI I Total Load I Compressive No. (Days) Test Date (lbs.) Strength (psi) Strength Required (psi) 119A 7 10/08 77000 2720 3000/28 DAYS B 28 10/29 94500 3340 C 28 10/29 103000 3640 D H Curing Method I Test Method Standard 6" x 12" Engineer/Technician R. LOVELADY ASTM C 31 I ASTM C 39 Area 28.27 sq. in. Signature: Mike Fuller, AET Supervisor, CMT~- L Remarks and/or Distribution Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting J LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.} or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:'.wpwin;reports\D7429-271-98'.ST C'c~ccer 3C, ", 998