Mansions Phase 1-LR 981028 Rone Engineers. Ir,c. !127~ Goodnight Lane Tel. (972) 241-4517 - RoneEngineers Oahas..'Fo¢. '¢,/oqh Dallas. Texas Metro (972) 263-155b ~ 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansions By .The Lake Page 1 of 4 Report No: 3137-D7429-293 Sample Date: October 22, 1998 Client: Western Rim Services Report Date: October 28, 1998 Location: Building//13 Technician: R. Lovelady # Tendon Location Jack Force Gauge Required Elongations Elongations Total Within No. (Kips) Pressure Elongations End (1) End (2) Elongations Tolerance 1 S-59 NORTH SIDE 33K 5700 4 518 4 1/2 YES 2 B-59 NORTH SIDE 33K 5700 4 5/8 4 1/2 YES 3 5-68 NORTH SIDE 33K 5700 5 3/8 5 3/4 YES 4 S-96 NORTH SIDE 33K 5700 7 1/2 7 1/2 YES 5 S-98.6 NORTH SIDE 33K 5700 7 3/4 8 YES 6 $-98.6 NORTH SIDE 33K 5700 7 3/4 7 112 YES 7 B-73.6 NORTH SIDE 33K 5700 5 5/8 6 YES 8 S-100 NORTH SIDE 33K 5700 7 7/8 7 1/2 YES 9 S-100 NORTH SIDE 33K 5700 7 7/8 8 YES 10 S-100 NORTH SIDE 33K 5700 7 7/8 7 3/4 YES Il B-73 NORTH SIDE 33K 5700 5 5/8 5 3/4 YES 12 S-96 NORTH SIDE 33K 5700 7 l/2 7 1/2 YES 13 S-96 NORTH SIDE 33K 5700 7 1/2 7 1/2 YES 14 S-96 NORTH SIDE 33K 5700 7 1/2 7 1/2 YES 15 S-96 NORTH SIDE 33K 5700 7 1/2 7 7/8 YES 16 S-98.6 NORTH SIDE 33K 5700 7 3/4 7 1/2 YES 17 B-71.6 NORTH SIDE 33K 5700 5 1/2 5 3/4 YES 18 S-98.6 NORTH SIDE 33K 5700 7 3/4 7 1/2 YES 19 S-98.6 NORTH SIDE 33K 5700 7 3/4 7 l/2 YES Equipmem ID: Ram No: 94016 Pump No: 380794 Gauge No: 94016 Equipment Calibration Date: 10/16/98 Comments: Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppell (I) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our leuers and reports are for the exclusive use of the clients to whom they are addressed. c:\wpwin\reports\D7429-293-98\ST October 28, 1998 '~ FIone Engineers, Inc. ~ 1~, Goodnight Lane TeL ~972) 241-4517 ~ ineers Da,las. gor~ Wo.Cm Dallas, Texas Metro (972) 263-!555 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansions By The Lake Page 2 of 4 Report No: 3137-D7429-293 Sample Date: October 22, 1998 Client: Western Rim Services Report Date: October 28, 1998 Location: Building #13 Technician: R. Lovelady # Tendon Location Jack Force Gauge Required Elongations Elongations Total Within No. (Kips) Pressure Elongatiom End (1) End (2) Elongatiom Tolerance 20 S-98.6 NORTH SIDE 33K 5700 7 3/4 7 3/4 YES 21 B-76 NORTH SIDE 33K 5700 6 5 7/8 YES 22 S-12.6 WEST SIDE 33K 5700 7/8 1 YES 23 S-26 NORTH SIDE 33K 5700 2 I 15/16 YES 24 S-26 NORTH SIDE 33K 5700 2 2 YES 25 S-26 NORTH SIDE 33K 5700 2 2 YES 26 B-27 SOUTH SIDE 33K 5700 2 1/8 2 YES 27 S-27 SOUTH SIDE 33K 5700 2 1/8 2 1/16 YES 28 S-46 SOUTH SIDE 33K 5700 3 5/8 3 1/2 YES 29 B-27 SOLrfH SIDE 33K 5700 2 I/8 2 1/8 YES 30 B-27 Sou'rH SIDE 33K 5700 2 1/8 2 1/8 YES 31 B-27 SOUTH SIDE 33K 5700 2 1/8 2 3/16 YES 32 B-27 SOUTH SIDE 33K 5700 2 1/8 2 1/4 YES 33 S-55 EAST SIDE 33K 5700 4 1/4 4 YES 34 B-55 EAST SIDE 33K 5700 4 1/4 4 YES 35 B-65.5 SOUTH SIDE 33K 5700 5 1/8 5 YES 36 S-60.6 EAST SIDE 33K 5700 4 3/4 4 3/4 YES 37 S-59.6 EAST SIDE 33K 5700 4 5/8 4 5/8 YES 38 S-59.6 EAST SIDE 33K 5700 4 5/8 4 9/16 YES Equipmem ID: Ram No: 94016 Pump No: 380794 Gauge No: 94016 Equipment Calibration Date: 10/16/98 Comments: Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (I) Mr. Mike Hodge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samptcs provided for tesdng. We assume no responsibility, for variation in quality. (composition, appearance, performance, etc.) or any o~her feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:"-.wpwin\reporW..D7429-293-98'.ST October 28, 1998 Rone Engineers, Inc. 11 ~ Goodnight Lane Tel. (972) 24!-4517 -- ineers Da,as. For1 VVo,!h ! Dallas. Texas bletro (972)~?lgq-l.~.~g=¢' 75229 Fax (972) 241 ~'-* ELONGATION REPORT Project: Mansions By The Lake Page 3 of 4 Report No: 3137-D7429-293 Sample Date: October 22, 1998 Client: Western Rim Services Report Date: October 28, 1998 Location: Building//13 Technician: R. Lovelady # Tendon Location Jack Force Gauge Required Elongations Elongations Total Within No. (Kips) Pressure Elongations End (1) End (2) Elongations Tolerance 39 B-59.6 EAST SIDE 33K 5700 4 5/8 4 5/8 YES 40 S-59.6 EAST SIDE 33K 5700 4 5/8 4 1/2 YES 41 S-62.6 EAST SIDE 33K 5700 4 7/8 5 3/8 YES 42 S-62.9 EAST SIDE 33K 5700 4 7/8 5 YES 43 B-62.9 EAST SIDE 33K 5700 4 7/8 5 YES 44 S-59 EAST SIDE 33K 5700 4 5/8 4 5/8 YES 45 S-59 EAST SIDE 33K 5700 4 5/8 4 7;8 YES 46 S-61.6 EAST SIDE 33K 5700 4 3/4 4 3/4 YES 47 B-61.6 EAST SIDE 33K 5700 4 3/4 5 YES 48 S-61.6 EAST SIDE 33K 5700 4 3/4 5 YES 49 S-59.6 EAST SIDE 33K 5700 4 5/8 4 5/8 YES 50 S-61.6 EAST SIDE 33K 5700 4 3/4 5 YES 51 S-61.6 EAST SIDE 33K 5700 4 3/4 5 1/$ YES 52 S-59.6 EAST SIDE 33K 5700 4 5/8 4 3/4 YES 53 S-59.6 EAST SIDE 33K 5700 4 5/8 4 3/4 YES 54 S-67 EAST SIDE 33K 5700 5 1/4 5 1/4 YES 55 B-67 EAST SIDE 33K 5700 5 1/4 5 1/4 YES 56 S-67 EAST SIDE 33K 5700 5 1/4 5 1/4 YES 57 S-67 EAST SIDE 33K 5700 5 1/4 5 1/8 YES Equipment ID: Ram No: 94016 Pump No: 380794 Gauge No: 94016 Equipment Calibration Date: 10/16/98 Comments: Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (I) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility, for variation in quality (composition. appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:~.wpwimreports\D7429-293-98",ST October 28, 1998 Rone Engineers. Inc. 112~-4 Goodnight Lane Tel. (972) 241-4517 -- ineers Oallas.-Fod Wort,~ Dallas. Texas Metro (972) 263-1555 75229 =ax (972) 241-5174 ELONGATION REPORT Project: Mansions By The Lake Page 4 of 4 Report No: 3137-D7429-293 Sample Date: October 22, 1998 Client: Western Rim Services Report Date: October 28, 1998 Location: Building #13 Technician: R. Lovelady # Tendon Location Jack Force Gauge Required Elongations Elongations Total Within No. (Kips) Pressure Elongations End (1) End (2) Elongations Tolerance 58 S-67 EAST SIDE 33K 5700 5 1/4 5 YES 59 B-67 EAST SIDE 33K 5700 5 I/4 5 1/4 YES 60 S-67 EAST SIDE 33K 5700 5 [/4 5 [/4 YES 61 S-67 EAST SIDE 33K 5700 5 1/4 5 YES 62 S-59 EAST SIDE 33K 5700 4 5/8 4 1/2 YES 63 S-29.6 EAST SIDE 33K 5700 2 1/4 2 3/8 YES 64 B-29.6 EAST SIDE 33K 5700 2 1/4 2 114 YES Equipment ID: Ram No: 94016 Pump No: 380794 Gauge No: 94016 Equipment Calibration Date: 10/16/98 Comments: Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (l) Mr. Mike Hodge; City of Coppell (l) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility, for variation in quality (composition, appearance, performance, etc.) or an)' o'21er feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:'.w?win\reporcs\D7429-293-98\ST October 28, 1998