Mansions Phase 1-LR 981028 (5) .one Engmneers. Inc.aooO,,g,t La,e RoneEngineers
J
Dallas.-Fo~ Wortr' Dallas, Texas Me'.ro (972) 263-1555
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansions By The Lake Purchase Order
Number 3137-D7429-264 I Date of Observation 9/29/98 Report Date 10/28/98
To Western Rim Services
Contractor
SupplierLATTIUORE IPlant 14 ITruck776 ITicket 14076827
Location SLAB ON GRADE - BUILDING//24 - 30' WEST, 15' SOUTH FROM NORTHEAST CORNER OF BUILDING
Time Sampled 9:00 Time Batched 7:50 Weather Condition CLEAR
Concrete Temperature (OF) 83 Ambient Temperature (°F) 80 Mix Number 51
Mix Description Unit Weight Water Added 5 GALLONS
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 7 1/2
Concrete Cylinder Test(s)
Specimen Age Test Date
No. (Days) (lbs.) Strength (psi) Strength Required (psi)
116A 7 10/06 59000 2090 3000/28 DAYS
B 28 10/27 85500 3020
C 28 10/27 85000 3010
D H
ASTM C 31 ASTM C 39 Area 28.27 sq. in.
Mike Fuller, AET Supervisor, CMT IJ~
L
Signature:
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Mike Hodge; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provideo for testing. We assume no
respons~b~iity for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by
persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are
addressed.
c:~.wpwimreports\D-7429-26498\ST Cc*.cber 28, ! 998