Mansions Phase 1-LR 981028 (7) Dallas. Fod Wo"th Dallas. Texas Metro (972) 263-1555
75229 ' Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansions By The Lake Purchase Order
Number 3137-D7429-267 Date of Observation 9/30/98 Report Date 10/28/98
To Western Rim Services
Contractor
Supplier LATTIMORE I Plant 3 I Truck 618 I Ticket 3071222
Location SLAB ON GRADE, BUILDING //1 - 20' SOUTH, 10' EAST FROM NORTHWEST CORNER OF BUILDING
Time Sampled 10:00 Time Batched 9:12 Weather Condition CLEAR
Concrete Temperature (°F) 86 Ambient Temperature (°F) 82 Mix Number 51
Mix Description Unit Weight Water Added 15 GALLONS
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 4 1/2
Concrete Cylinder Test(s)
Specimen Age Test Date
No. (Days) (lbs.) Strength (psi) Strength Required (psi)
118A 7 10/07 71000 2510 3000/28 DAYS
B 28 10/28 85000 3010
C 28 10/28 90000 3180
D H
I
I
Curing Method I Test Method Standard 6" x 12" I Engineer/Technician R. LOVELADY
ASTM C 31 I ASTM C 39 Area 28.27 sq. in.
I
Signature: Mike Fuller, AET Supervisor, CMT ~.
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Mike Hedge; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The test results presented herein were prepared based upon the specific samples prowded for testing. We assume no
responsibility for variation ~n quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by
persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are
addressed.
c:twpwin..reports\D7429-267-98~ST C:tobe, 28, 1998