Mansions Phase 1-LR 981026 (4) Da;,as.F.3c WoC..q Dallas. Texas Metro (972) 263-1555 75229 Pax (.972) 24i-5174 Concrete Cylinder Test Report Project Mansions By The Lake Purchase Order Number 3137-D7429-285 Date of Observation 10,'14/98 Report Date 10/26/98 To Western Rim Services Contractor Supplier LATTIMORE Plant 6 I Truck 939 I Ticket 6082378 Location BUILDING PAD #15 - 30' SOUTH, 15' WEST FROM NORTHEAST CORNER OF BUILDING PAD Time Sampled 8:30 Time Batched 8:00 Weather Condition PT CLOUDY Concrete Temperature (°F) 77 Ambient Temperature (°F) 64 Mix Number 51 Mix Description Unit Weight Water Added 15 GALLONS Physical Data ACTUAL SPECIFICATIONS SLUMP (in.) 5.0 Concrete Cylinder Test(s) Specimen Age Test Date No. (Days) (lbs.) Strength (psi) Strength Required (psi) 124A 7 10/21 67000 2370 3000/28 DAYS B 28 I 1/11 C 28 11/11 D H Curing Method Test Method Standard 6" x 12" Engineer/Technician R. LOVELADY ASTM C 31 ASTM C 39 Area 28.27 sq. in. Signature: Mike Fuller, AET Supervisor, CMT ~1~ Remarks and/or Distribution Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hedge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation m quality (composition, appearance, performance, etc.) or any other feature of simdar subject matter prowded by persons or conditions over which we have .no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:'wowm.reports'D7429-255-98-ST October 26, ' 998