Loading...
Mansions Phase 1-LR 981026 (7) Da;,as.-Fo,'l' Wodh Dallas. Texas rvle.tro (972) 263-I 55.5 75229 Fax (972) 241-5174 Concrete Cylinder Test Report Project Mansions By The Lake Purchase Order Number 3137-D7429-288 I Date of Observation 10il 5/98 Report Date 10¢'26.-.'98 To Western Rim Services Contractor Location SLAB ON GRADE, BUILDING #32 - 30' EAST, 15' NORTH FROM SOUTHEAST CORNER OF BUILDING Time Sampled 8:15 Time Batched 7:15 Weather Condition CLEAR Concrete Temperature I°F) 78 Ambient Temperature (°F) 66 Mix Number 51 Mix Description Unit Weight Water Added 10 GALLONS Physical Data ACTUAL SPECIFICATIONS SLUMP (in.) 6 1/2 Concrete Cylinder Test(s) No. (Days) (lbs.) Strength (psi) Strength Required (psi) 126A 7 10/22 74000 2620 3000/28 DAYS B 28 11/12 C 28 I 1/12 D H Curing Method Test Method Standard 6" x 12" Engineer/Technician R. LOVELADY ASTM C 31 ASTM C 39 Area 28.27 sq. in. Signature: Mike Fuller, AET Supervisor, CMT~I~I~ Remarks and/or Distribution Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting L. MITATICNS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume r,c res;)ons~bility for variation in quality (compos,tion, appearance, performance, etc.) or any other feature of similar subject matter provided b'¢ persons or conditions over whicl~ we have no control. Our ~etters and reDor[s are for the exclusive use of the clients to whom the,/ are acdressed. c: wpwim:ecorts:D7429-28S-98' ST Cc:coer 26, 1998