Mansions Phase 1-LR 981026 (7) Da;,as.-Fo,'l' Wodh Dallas. Texas rvle.tro (972) 263-I 55.5
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansions By The Lake Purchase Order
Number 3137-D7429-288 I Date of Observation 10il 5/98 Report Date 10¢'26.-.'98
To Western Rim Services
Contractor
Location SLAB ON GRADE, BUILDING #32 - 30' EAST, 15' NORTH FROM SOUTHEAST CORNER OF BUILDING
Time Sampled 8:15 Time Batched 7:15 Weather Condition CLEAR
Concrete Temperature I°F) 78 Ambient Temperature (°F) 66 Mix Number 51
Mix Description Unit Weight Water Added 10 GALLONS
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 6 1/2
Concrete Cylinder Test(s)
No. (Days) (lbs.) Strength (psi) Strength Required (psi)
126A 7 10/22 74000 2620 3000/28 DAYS
B 28 11/12
C 28 I 1/12
D H
Curing Method Test Method Standard 6" x 12" Engineer/Technician R. LOVELADY
ASTM C 31 ASTM C 39 Area 28.27 sq. in.
Signature: Mike Fuller, AET Supervisor, CMT~I~I~
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Mike Hodge; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
L. MITATICNS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume r,c
res;)ons~bility for variation in quality (compos,tion, appearance, performance, etc.) or any other feature of similar subject matter provided b'¢
persons or conditions over whicl~ we have no control. Our ~etters and reDor[s are for the exclusive use of the clients to whom the,/ are
acdressed.
c: wpwim:ecorts:D7429-28S-98' ST Cc:coer 26, 1998