Mansions Phase 1-LR 981021 Cal,as.-'ro~ Wo,tn ; Dallas. Texas Metro (972) 263-155b : 75229 Fax (972) 241-5174 Concrete Cylinder Test Report Project Mansions By The Lake Purchase Order Number 3137-D7429-249 I Date of Observation 9/21/98 Report Date 10i21/98 To Western Rim Services Contractor Location BUILDING #17 - 25' EAST, 40' SOUTH FROM NORTHWEST CORNER OF BUILDING Time Sampled 8:05 Time Batched 7:55 Weather Condition CLEAR Concrete Temperature (OF) 83 Ambient Temperature (°F) 74 Mix Number 51 Mix Description Unit Weight Water Added NONE Physical Data ACTUAL SPECIFICATIONS SLUMP (in.) 4 1/2 Concrete Cylinder Test(s) No. (Days) Test Date (lbs.) Strength (psi) Strength Required (psi) 109A 7 9/28 76000 2690 3000/28 DAYS B 28 10/19 109500 3870 C 28 10/19 102500 3630 D H I Curing Method I Test Method Standard 6" x 12" Engineer/Technician R. LOVELADY ASTM C 31 I ASTM C 39 Area 28.27 sq. in. Signature: Mike Fuller, AET Supervisor, CMT~( Remarks and/or Distribution Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hedge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting ~IMiTATIONS: The test results presented hereto were prepared aased upon the specific samples prowded for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.! or any other feature of similar subject matter provided by persons or conditions over 'which 'we have no control. Our letters and reports are for the exclusive use of the clients ~o whom they are addressed. C: Wowin reports'.D7429-2~9-98~.S- Cctcber 21, 1998