Mansions Phase 1-LR 981021 Cal,as.-'ro~ Wo,tn ; Dallas. Texas Metro (972) 263-155b
: 75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansions By The Lake Purchase Order
Number 3137-D7429-249 I Date of Observation 9/21/98 Report Date 10i21/98
To Western Rim Services
Contractor
Location BUILDING #17 - 25' EAST, 40' SOUTH FROM NORTHWEST CORNER OF BUILDING
Time Sampled 8:05 Time Batched 7:55 Weather Condition CLEAR
Concrete Temperature (OF) 83 Ambient Temperature (°F) 74 Mix Number 51
Mix Description Unit Weight Water Added NONE
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 4 1/2
Concrete Cylinder Test(s)
No. (Days) Test Date (lbs.) Strength (psi) Strength Required (psi)
109A 7 9/28 76000 2690 3000/28 DAYS
B 28 10/19 109500 3870
C 28 10/19 102500 3630
D H
I
Curing Method I Test Method Standard 6" x 12" Engineer/Technician R. LOVELADY
ASTM C 31 I ASTM C 39 Area 28.27 sq. in.
Signature: Mike Fuller, AET Supervisor, CMT~(
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Mike Hedge; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
~IMiTATIONS: The test results presented hereto were prepared aased upon the specific samples prowded for testing. We assume no
responsibility for variation in quality (composition, appearance, performance, etc.! or any other feature of similar subject matter provided by
persons or conditions over 'which 'we have no control. Our letters and reports are for the exclusive use of the clients ~o whom they are
addressed.
C: Wowin reports'.D7429-2~9-98~.S- Cctcber 21, 1998