Mansions Phase 1-LR 981021 (2) Da,,as. Fcc ',",,/o~n Dallas. Texas :Metro (972) 263-1555
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansions By The Lake Purchase Order
Number 3137-D7429-250 I Date of Observation 9/21;'98 Report Date 10/21/98
To Western Rim Services
Contractor
Supplier LATTIMORE I Plant 6 I Truck 805 I Ticket 6080581
Location BUILDING #17 - 15' WEST, 15' NORTH FROM SOUTHEAST CORNER OF BUILDING
Time Sampled 9:30 Time Batcned N/A Weather Condition CLEAR
Concrete Temperature (°F) 82 Ambient Temperature (°F) 81 Mix Number 57
Mix Description Unit Weight Water Added NONE
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 6.0
Concrete Cylinder Test(s)
Specimen Age Test Date
No. (Days) (lbs.) Strength (psi) Strength Required (psi)
110A 7 9/28 64000 2260 3000/28 DAYS
B 28 10/19 87500 3100
C 28 10/19 93000 3290
D H
Curing Method I Test Method Standard 6" x 12" Engineer/Technician R. LOVELADY
ASTM C 31 I ASTM C 39 Area 28.27 sq. in.
Signature: Mike Fuller, AET Supervisor, CMT~f~/
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Mike Hodge; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
L~MITATIONS: The test results presented herein were prepared based bpon ;he specific samples provided for testing. We assume no
responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by
persons cr conditions over which vve have no control. Our letters and reports are for the exclusive use of ',he clients to whom thev are
acdressed.
c: wpwin'.repo.'Zs'.D7" 2.9-250-98'.ST October 2~, , 1998