Loading...
Mansions Phase 1-LR 981014 (2) Rone Engineers. Inc. 11 2~-* Goodnlgh! Lane Tei. (972) 241-4517 Da~,as.-Fo,i Wonp Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 Concrete Cylinder Test Report Project Mansions By The Lake Purchase Order Number 3137-D7429-275 I Date of Observation 10/O2/98 Report Date 10/14:'98 To Western Rim Services Contractor Supplier LATTIMORE I Plant 6 I Truck 615 I Ticket 6081663 Location SLAB ON GRADE, BUILDING #23 - 25' EAST, 10' NORTH FROM SOUTHWEST CORNER OF BUILDING Time Sampled 9:30 Time Batched 8:10 Weather Condition CLOUDY Concrete Temperature (°F) 79 Ambient Temperature (°F) 75 Mix Number 51 Mix Description Unit Weight Water Added NONE Physical Data ACTUAL SPECIFICATIONS SLUMP (in.) 6.0 Concrete Cylinder Test(s) Specimen Age Test Date No. (Days) (lbs.) Strength (psi) Strength Required (psi) 1 22A 7 10/09 66500 2350 3000/28 DAYS B 28 10~30 C 28 10/30 D H Curing Method ] Test Method I Standard 6" x 12"I Engineer/Technician R. LOVELADY ASTM C 31 ] ASTM C 39 ~LxArea 28.27 sq. in. ] Signature: Mike Fuller, AET I'&,/Supervisor, CMT Remarks and/or Distributionk'%_ Distribution: (1) Mr. Richard E. Simmons; Western Rim Services {1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples prowded for testing. We assume no responsibiiitv for variation in quality (composition, appearance, performance, etc.) or any other feature of s~mdar subject matter prowded by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:-wpwin'.reports'.D7429-275-98'.ST Oc~ooer ' 4, 1998