Mansions Phase 1-LR 981014 (3) Rone Engineers, Inc. 112~--' Goodnight Lane Tei. (972) 241-4517 - RoneEn_qineers
Da~ias.'For~ ','Voil, r' Dallas, Texas Metro (972) 263-1555
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansions By The Lake Purchase Order
Number 3137-D7429-242 I Date of Observation 9/11/98 Report Date 10/14/98
To Western Rim Services
Contractor
Supplier LATTIMORE I Plant 6 I Truck 804 Ticket 6080078
I
I
Location SLAB ON GRADE, BUILDING #20 - 20' NORTH BY 10' WEST FROM SOUTHEAST CORNER
Time Sampled N/A Time 5~tch 6:00 Weather Condition CLOUDY
Concrete Temperature (°F) 88 Ambient Temperature (°F) N/A Mix Number 51
Mix Description Unit Weight Water Added NONE
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 5.0
ENTRAINED AIR (%) 5.0
Concrete Cylinder Test(s)
No. (Days) Test Date (lbs.) Strength (psi) Strength Required (psi)
107A 7 9/18 76000 2690 3000/28 DAYS
B 28 10/9 106000 3750
C 28 1019 107000 3780
D H
ASTM C 31 ASTM C 39 Area 28.27 sq. in.
Signature: MiKe Fuller, AET ~'~ Supervisor, CMT
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Mike Hodge; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
L;MITAT'.CNS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no
resoonsibility for variation ~n quality {composition, appearance, performance, etc.) or any other feature of similar subject matter provided bv
persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom the,/ are
addressed.
c:-.wpwm:reportstD7429-242-98'tST October 14, 1998