Loading...
Mansions Phase 1-LR 981014 (4) D~l,as..'Fo~ Wcd,,n Dallas. Texas Metro (972) 263-I 555 75229 Fax (972) 241-5174 Concrete Cylinder Test Report Project Mansions By The Lake Purchase Order Number 3137-D7429-243 I Date of Observation 9/11/98 Report Date 10/14/98 To Western Rim Services Contractor Location SLAB ON GRADE, BUILDING 320 - 20' NORTH BY 30' EAST FROM SOUTHWEST CORNER Time Sampied 8:30 Time Batch 7:56 Weather Condition CLOUDY Concrete Temperature (CF) 89 Ambient Temperature (°F) N/A Mix Number 51 Mix Description Unit Weight Water Added 10 GALLONS Physical Data ACTUAL SPECIFICATIONS SLUMP (in.) 6.0 ENTRAINED AIR (%) 4.5 Concrete Cylinder Test(s) Specimen Age Test Date No. (Days) (lbs.) Strength (psi) Strength Required (psi) 10SA 7 9/18 75000 2650 3000/28 DAYS B 28 10/9 110000 3890 C 28 10/9 105000 3710 D H Curing Method Test Method Standard 6" x 12" Engineer/Technician J. BOSTER ASTM C 31 ASTM C 39 Area 28.27 sq. in. Signature: Mike Fuller, AET~ Supervisor, CMT Remarks and/or Distribution Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting L. MITATICNS: The test results presented herein were prepared based upon the spec:ftc samples provided for testing. We assume no respons~bdity for variation in quality {composition, appearance, performance, etc.) or any other feature cf s~milar subject matter prowded by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c: wpwintreoorts'..D7429-243-98'ST October: 4, 1998