Mansions Phase 1-LR 981014 (6) .one Eng,neers. Inc. l l 2' ,Oooanlgtll Lane - RoneEngJneers
Dai.as.-'Fcc Worth Dallas. Texas Metro (972) 263-1555
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansions By The Lake Purchase Order
Number 3137-D7429-266 I Date of Observation 9/30/98 Report Date 10/14/98
To Western Rim Services
Contractor
Supplier LATTIMORE J Plant 7 J Truck 610 J Ticket 7059289
Location SLAB ON GRADE, BUILDING #1 - 25' WEST, 20' NORTH FROM SOUTHEAST CORNER OF BUILDING
Time Sampled 7:40 Time Batched 7:11 Weather Condition CLEAR
Concrete Temperature (CF) 82 Ambient Temperature (OF) 68 Mix Number 51
Mix Description Unit Weight Water Added NONE
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 3.0
Concrete Cylinder Test(s)
Specimen Age Test Date
No. (Days) (lbs.) Strength (psi) Strength Required (psi)
117A 7 10/07 72000 2550 3000/28 DAYS
B 28 10/28
C 28 10/28
D H
Curing Method I Test Method I Standard 6" x12" I EngineerlTechnicianR. LOVELADY
ASTM C 31 ASTM C 39 Area 28.27 sq. in.
Signature: Mike Fuller, AET ~} Supervisor, CMT
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Mike Hodge; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C, D. Construction Consulting
LiMITATiONS: The test results presented herein were prepared based upon the specific samples orowded for testing. We assume no
responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of simdar subject matter provided by
persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are
addressed.
c:'wpwin.repcrts'.D7429-266-98'.ST October 14, 1998