Loading...
Magnolia Park-CS 970811The City With A Beautiful Future August 11, 1997 Guermo Juarez Dowdey, Anderson and Associates, Inc. 16250 Dallas Parkway, Suite 100 Dallas, TX 75248 RE: Magnolia Park / Construction Plans Dear Mr. Juarez: The City of Coppell has received and reviewed the referenced plans and has ~ to offer: 1. Please label the alleys on the plat. 2. Sidewalks need to be provided along Natches Trace at the entrance These sidewalks need to be constructed when the streets are paved. 3. The temporary asphalt pavement at the entrance must be on a 6" lirr 4. At the entrance of Natches Trace, the street needs to be a minimum Fire Department requirements. 5. Provide a detail of the Denton Tap Road and Natches Trace showing left turn lane. 6. Remove the sentence from General Note//7 which states "Future 1~ SD7, by home builder at time of home construction, typical pla intersection." The barrier free ramps must be built by the develope 7. Provide pavement grades for the proposed invert on Stanton Hall 12 11 +00 and 12 +00. 8. On the typical alley section on Plate //12, provide the dimension stabilized outside the limit of concrete paving. 9. At the intersection of alley "A-2" with alley "A-l" provide a tra~ drainage in alley "A-2" to alley "A-l" (see Plate//12). 10. The drainage area map is missing proposed storm sewer inlets. 11. Show the proposed storm sewer inlets on Natches Trace at approx~ 10+00. 12. Show the correct street names on Plate//3. 13. Provide a TxDOT detail for proposed Type MCW-F1 headwall, l detail for proposed safety runners. 14. Label proposed and existing grade lines on all the storm sewer profi 15. Provide railing or fence across the top and sides of headwall for the PCB. P.O. Box 478 Coppell, Texas 75019 214-462-0022 e following comments of this development. e stabilized subgrade. ~f 24' wide as per the deceleration lane and artier-Free Ramp per n at all minor street ~rive between stations )f the subgrade to be sition invert to allow ~ate Stations 8+50 & dso, provide TxDOT les. proposed 2 - 9' x 6' 16. Can the proposed grade to drain between the 2 - 24" RCP in the co: Trace be accomplished with the existing trees in this area. 17. Provide note stating "All utility crossing within 24" of each must b, 18. Provide railing or fence across the top of the proposed 3 - 7' x 4' 19. Label all the lots and blocks on the storm sewer plan views and sho~ easements. 20. Show the water service for all lots at the center of lot and sanitary feet downstream of water service line. 21. Provide 2" blowoff on all deadend water lines. 22. Make addition to water and sewer note #27 to include mandrel test. 23. On the grading plans, plate #30, Lot 2, Block B should be graded s, instead of the back, between Lots 4 and 5, Block B. 24. Provide grading plans for Natches Trace/Denton Tap Road intersect There are various other minor comments throughout the plans. Once these addressed, the marked up plans along with two revised sets of plans should City for review. If any major changes occur please indicate on the plans. I questions concerning these comments, please contact me at 304-3681. Sincerely Michael A. Martin, P.E. Assistant City Engineer ninon area of Natches ; concrete encased". ',CB (see Plate #23). the width of drainage sewer service lines 10 it drains to the front )n. comments have been be resubmitted to the you should have any