Loading...
Mansions Phase 1-LR 981013 (5) Rone Engineers, Inc. = 112' '-- Goodnight Lane Tel. (972} 241-4517 RoneEn ineers Da~ias.-'For: Worth Dallas, Texas Metro (972) 263-1555 75229 , Fax (972) 241-5174 ELONGATION REPORT Project: Mansions By The Lake Page 1 of 4 Report No: 3137~D7429-277 Sample Date: October 6, 1998 Client: Western Rim Services Report Date: October 13, 1998 Location: Building g24 Technician: R. Lovelady # Tendon Location Jack Force Gauge Required Elongations Elongations Total Within No. (Kips) Pressure Elongations End (1) End ~2) Elongations Tolerance I S-59 N Side E-W 33K 5500 4 518 4 5,'8 YES 2 B-59 N Side E-W 33K 5500 4 5/8 4 3/4 YES 3 S-68 N Side E-W 33K 5500 5 3/8 5 1/4 YES 4 S-96 N Side E-W 33K 5500 7 1/2 7 YES 5 S-98.6 N Side E-W 33K 5500 7 3/4 7 Ii2 YES 6 S-98.6 N Side E-W 33K 5500 7 3;4 7 3/8 YES ? B-73.6 N Side E-W 33K 5500 5 5;8 5 3.,'8 YES 8 S-100 N Side E-W 33K 5500 7 7;8 7 3/8 YES 9 S-100 N Side E-W 33K 5500 7 7/8 7 3/8 YES i0 S-100 N Side E-W 33K 5500 7 7/8 7 5/6 YES 11 B-73 N Side E-W 33K 5500 5 5;'8 5 1,:4 YES 12 S-96 N Side E-W 33K 5500 7 1/2 7 YES 13 S-96 N Side E-W 33K 5500 7 1/2 7 1/8 YES 14 S-96 N Side E-W 33K 5500 7 1/2 7 1/4 YES 15 S-96 N Side E-W 33K 5500 7 1/2 7 3i16 YES 16 S-98.6 N Side E-W 33K 5500 5 1/2 5 5/8 YES 17 B-71.6 N Side E-W 33K 5500 7 3.:4 7 3/16 YES 18 S-98.6 N Side E-W 33K 5500 7 3,,'4 7 1/2 YES 19 S-98.6 N Side E-W 33K 5500 7 3/4 7 5/8 YES Equipment ID: Ram No: 93014 Pump No: 381996 Gauge No: 93014 Equipment Calibration Date: 9/04/98 Comments: Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quali~: ~composition. appearance, performance, etc.'~ or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c::wpwin'..reports'..D7429-277-98\ST October 13. 1998 Rone Engineers. Inc. ! 1 ;' -' Goodnight Lane Tel. (972) 241-4517 Rone En_qineers Dailas.-Fort Wodh Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansions By The Lake Page 2 of 4 Report No: 3137-D7429-277 Sample Date: October 6, 1998 Client: Western Rim Services Report Date: October 13, 1998 Location: Building//24 Technician: R. Lovelady # Tendon Location Jack Force Gauge Required Elongations Elongations Total Within No. (Kips) Pressure Elongations End (1) End ¢2) Elongations Tolerance 20 S-98,6 N Side E-W 33K 5500 7 3/4 7 1;2 YES 21 B-76 N Side E-W 33K 5500 6 5 5,'8 YES 22 S-12.6 N Side E-W 33K 5500 7/8 1 YES 23 S-26 N Side E-W 33K .... 5500 2 2 YES 24 S-26 N Side E-W 33K 5500 2 1 7i8 YES 25 S-26 N Side E-W 33K 5500 2 I 7/8 YES 26 B-27 S Side W-E 33K 5500 2 I/8 2 YES ~.,'¥' S-27 S Side W-E 33K 5500 ~'~ 118 2 YES 28 S-46 S Side W-E 33K 5500 3 5/8 3 3/8 YES 29 B-27 S Side W-E 33K 5500 2 1/8 2 1/8 YES 30 B-27 S Side W-E 33K 5500 2 i/8 2 1/8 YES 31 B-27 S Side W-E 33K 5500 2 1/8 2 1/4 YES 32 B-27 S Side W-E 33K 5500 2 1/8 2 1/8 YES 33 S-55 S Side W-E 33K 5500 4 1/4 3 7/8 YES 34 B-55 S Side W-E 33K 5500 4 1/4 3 7/8 YES 35 B-65.5 S Side W-E 33K 5500 5 1/8 4 13/16 YES 36 S-60.6 East Side S-N 33K 5500 4 3/4 4 5i8 YES 37 S-59.6 East Side S-N 33K 5500 4 5i8 4 5/8 YES 38 S-59.6 East Side S-N 33K 5500 4 5;8 4 1i2 YES Equipment ID: Ram No: 93014 Pump No: 381996 Gauge No: 93014 Equipment Calibration Date: 9/04/98 Comments: Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; Cit7 of Coppell (1) Mr. Mike Hodge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition. appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:'.wpwin~.reports'..D7429-277-98',ST October 13. 1998 Rone Engineers. Inc. 11'-- Goodnight Lane Tei. (972) 241-4517 RoneEngineers Da!las. Fo.-1. Won. h Dallas. Texas Metro (972) 263-1555 75229 , Fax (972) 241-5174 ELONGATION REPORT Project: Mansions By The Lake Page 3 of 4 Report No: 3137-D7429-277 Sample Date: October 6, 1998 Client: Western Rim Services Report Date: October 13, 1998 Location: Building//24 Technician: R. Lovelady # Tendon Location Jack Force Gauge Required Elongations Elongations Total Within No. fKips~ Pressure Elongations End (1) End (2'~ Elongations Tolerance 39 B-59.6 East Side S-N 33K 5500 4 5/8 4 1/2 YES 40 S-59.6 East Side S-N 33K 5500 4 5/8 4 3;8 YES 41 S-62.6 East Side S-N 33K 5500 4 7/8 4 5/8 YES 42 S-62.9 East Side S-N 33K .... 5500 4 7/8 4 5/8 YES 43 B-62.9 East Side S-N 33K 5500 4 7/8 4 1,'2 YES 44 S-59 East Side S-N 33K 5500 4 5i8 4 3/4 YES 45 S-59 East Side S-N 33K 5500 4 5/8 4 3/8 YES 46 S-61.6 East Side S-N 33K 5500 4 3/4 4 5/8 YES 47 B-61.6 East Side S-N 33K 5500 4 3/4 4 1/2 YES 48 S-61.6 East Side S-N 33K 5500 4 3/4 4 i/2 YES 49 S-59.6 East Side S-N 33K 5500 4 5/8 4 3/8 YES 50 S-61.6 East Side S-N 33K 5500 4 3/4 4 1/2 YES 51 S-61.6 East Side S-N 33K 5500 4 3/4 4 5/8 YES 52 S-59.6 East Side S-N 33K 5500 4 5/8 4 3/4 YES 53 S-59.6 East Side S-N 33K 5500 4 5/8 4 3/8 YES 54 S-67 East Side S-N 33K 5500 5 1;4 5 YES 55 B-67 East Side S-N 33K 5500 5 1/4 5 YES 56 S-67 East Side S-N 33K 5500 5 1/4 5 YES 57 S-67 East Side S-N 33K 5500 5 I/4 5 1.,'8 YES Equipment ID: Ram No: 93014 Pump No: 381996 Gauge No: 93014 Equipment Calibration Date: 9/04/98 Comments: Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppell (I) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no respons~bili~' for variation in qualiD' (composition. appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c::wpwin'..reports~.D7429-277-98',ST October 13. 1998 Rone Engineers, Inc. 11'-" Goodnight Lane Tel. (972) 241-4517 RoneEn_qineers . Da~las.-'Fort Worth Dallas. Texas Metro (972) 263-1555 ~, 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansions By The Lake Page 4 of 4 Report No: 3137-D7429-277 Sample Date: October 6, 1998 Client: Western Rim Services Report Date: October 9, 1998 Location: Building #24 Technician: R. Lovelady # Tendon Location Jack Force Gauge Required Elongations Elongations Total Within No. (Kips'~ Pressure Elongations End (1) End (2) Elongations Tolerance 58 S-67 East Side S-N 33K 5500 5 1/4 5 1/8 YES 59 B-67 East Side S-N 33K 5500 5 1/4 5 1/4 YES 60 S-67 East Side S-N 33K 5500 5 1/4 5 YES 61 S-67 East Side S-N 33K ~_5500 5 1/4 5 1/8 YES 62 S-59 East Side S-N 33K 5500 4 5/8 4 3/8 YES 63 S-29.6 East Side S-N 33K 5500 2 1/4 2 3/8 YES 64 B-29.6 East Side S-N 33K 5500 2 1!4 2 3/8 YES Equipment ID: Ram No: 93014 Pump No: 381996 Gauge No: 93014 Equipment Calibration Date: 9/04/98 Comments: Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quali~' (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:':wpwin'.reports~.D7429-277-98',ST October 13, 1998