Loading...
Mansions Phase 1-LR 981009 (4) Rone Engineers. Inc. 112-- ooO,,g ,,a,e Te,. ( 72) - RoneEngineers Dal,as.'Fo,q Worlr' Dallas, Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansions By The Lake Page 1 of 4 Report No: 3137-D7429-247 Sample Date: September 17, 1998 Client: Western Rim Services Revised: October 9, 1998 Location: Building 20 Technician: R. Lovelady # Tendon Location Jack Force Gauge Required Elongations Elongations Total Within i No. (Kips) Pressure Elongations End (1) End (2'~ Elongations Tolerance I 1 S-27 SW Corner 33K 5500 2 1;8 2 1:'4 YES 2 B-27 WEST 33K 5500 2 1;8 2 1;8 YES 3 S-46 WEST 33K 5500 3 5/8 3 3;4 YES 4 B-27 WEST 33K 5500 2 1/8 2 1/8 YES 5 B-27 WEST 33K 5500 2 1,'8 2 YES 6 B-27 WEST 33K 5500 2 1;8 2 YES 7 B-27 WEST 33K 5500 2 1;8 2 3/16 YES 8 S-55 SE Corner 33K 5500 4 1;4 4 1/4 YES 9 B-55 SOLrrH 33K 5500 4 1/4 4 3/16 YES 10 B45.5 SOLrl'H 33K 5500 5 1/8 4 7/8 YES 11 S-60.6 SOUTH 33K 5500 4 3/4 4 9/16 YES 12 S-59.6 SOUTH 33K 5500 4 5/8 5 YES 13 B-59.6 SOUTH 33K 5500 4 5/8 4 9/16 YES 14 S-59.6 SOUTH 33K 5500 4 5/8 4 5.."8 YES 15 S-59.6 SOUTH 33K 5500 4 5/8 4 5/8 YES 16 S-62.6 SOUTH 33K 5500 4 7/8 4 7/8 YES 17 S-62.9 SOUTH 33K 5500 4 7/8 5 3116 YES 18 B-62.9 SOLrrH 33K 5500 4 7;8 4 13/16 YES 19 S-59 SOUTH 33K 5500 4 5/8 4 3i4 YES Equipment ID: Ram No: 93014 Pump No: 381996 Gauge No: 93014 Equipment Calibration Date: 7/29/98 Comments: Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality tcomposition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:'.wpwin'.reports'.D7429-247-98'.ST October 12, 1998 Roue Engineers. Inc. 11' Goodnight Lane Tel. (972) 241-4517 RoneEn_qineers Da,,as:'Forl, Worth Dallas. Texas Metro (972) 263-1555 i 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansions By The Lake Page 2 of 4 Report No: 3137:D7429-247 Sample Date: September 17, 1998 Client: Western Rim Services Revised: October 9, 1998 Location: Building 20 Technician: R. Lovelady # Tendon Location Jack Force Gauge Required Elongations Elongations Total Within No. (Kips~ Pressure Elongations End (I) End (2) Elongations Tolerance 20 S-59 SOUTH 33K 5500 4 5/8 4 5/8 YES 21 S-61.9 SOUTH 33K 5500 4 3/4 4 3/4 YES 22 B-61.6 SOUTH 33K 5500 4 3/4 5 1/4 YES 23 S-61.6 SOUTH 33K 5500 4 3/4 5 1/8 YES 24 S-59.6 SOUTH 33K 5500 4 5/8 4 7/8 YES 25 S-61.6 SOL'TH 33K 5500 4 3/4 4 3/4 YES 26 B-61.6 SOUTH 33K 5500 4 3/4 4 3/4 YES 27 S-59.6 SOL'TH 33K 5500 4 5/8 4 3/4 YES 28 S-59.6 SOL'TH 33K 5500 4 5/8 4 3/4 YES 29 S-67 SOUTH 33K 5500 5 1/4 5 I/2 YES 30 B-67 SOL'TH 33K 5500 5 1/4 5 3/8 YES 31 S-67 SOL'TH 33K 5500 5 1/4 5 7/16 YES 32 S-67 SOUTH 33K 5500 5 1/4 5 3/8 YES 33 S-67 SOUTH 33K 5500 5 1/4 5 1/4 YES 34 B-67 SOUTH 33K 5500 5 1/4 5 3/4 YES 35 S-67 SOL]TH 33K 5500 5 1i4 5 3/8 YES 36 S-67 SOUTH 33K 5500 5 1/4 5 3/16 YES 37 S-59 SOUTH 33K 5500 4 5i8 4 7/16 YES 38 S-29.6 SOUTH 33K 5500 2 1/4 2 3/8 YES Equipment ID: Ram No: 93014 Pump No: 381996 Gauge No: 93014 Equipment Calibration Date: 7/29/98 Comments: Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (I) Mr. Lar~, Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality tcomposition, appearance, pertbrmance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:'.wpwin'~reports\D7429-247-98~.ST October 12, 1998 Rone Engineers, Inc. 11 ," Goodnight Lane Tel. (972) 241-4517 RoneEngineers Dallas:Fort Worth Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansions By The Lake Page 3 of 4 Report No: 3137-D7429-247 Sample Date: September 17, 1998 Client: Western Rim Services Revised: October 9, 1998 Location: Building 20 Technician: R. Lovelady # Tendon Location Jack Force Gauge Required Elongations Elongations Total Within No. (Kips) Pressure Elongations End (1) End (2'~ Elongations Tolerance 39 B-29.6 WEST 33K 5500 2 I/4 2 1/4 YES 40 S-59 NECorner 33K 5500 4 5/8 4 15/16 YES 41 B-59 EAST 33K 5500 4 5,'8 4 1/2 YES 42 S-68 EAST 33K 5500 5 3/8 5 1/4 YES 43 S-96 EAST 33K 5500 7 1/2 7 1/2 YES 44 S-98.6 EAST 33K 5500 7 3/4 7 5/8 YES 45 S-98.6 EAST 33K 5500 7 3/4 7 3/4 YES 46 B-73.6 EAST 33K 5500 5 5/8 5 3/4 YES 47 S-100 EAST 33K 5500 7 7/8 7 1/2 YES 48 S-100 EAST 33K 5500 7 7/8 7 7/16 YES 49 S-100 EAST 33K 5500 7 7/8 7 3/4 YES 50 B-73 EAST 33K 5500 5 5;8 5 3/4 YES 51 S-96 EAST 33K 5500 7 1/2 7 1/4 YES 52 S-96 EAST 33K 5500 7 1;2 7 9/16 YES 53 S-96 EAST 33K 5500 7 1/2 7 3/8 YES 54 S-96 EAST 33K 5500 7 1/2 7 1/2 YES 55 S-98 EAST 33K 5500 7 3/4 7 1/2 YES 56 B-71.6 EAST 33K 5500 5 1;2 5 1/4 YES 57 S-98.6 EAST 33K 5500 7 3/4 7 1/2 YES Equipment ID: Ram No: 93014 Pump No: 381996 Gauge No: 93014 Equipment Calibration Date: 7/29/98 Comments: *Elongation from table. Technician did interpolation between 69 & 71 to get elongation for 70. Distribution: (I) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no respons:bili~' for variation in quali~' {.composinon, appearance, performance, etco or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:'.wpwin'.reports\D7429-247-98'.ST October 12. 1998 Rone Engineers, Inc. 11' -' Goodnight Lane Tel. (972) 241-4517 RoneEn ineers Ca,las. For1 ','Vo'lh , Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansions By The Lake Page 4 of 4 Report No: 3137-D7429-247 Sample Date: September 17, 1998 Client: Western Rim Selwices Revised: October 9, 1998 Location: Building 20 Technician: R. Lovelady # Tendon Locadon Jack Force Gauge Required Elongations Elongations Total Within No. ~3;~ips} Pressure Elongations End (1) End (2} Elongations Tolerance 58 S98.6 EAST 33K 5500 7 3/4 7 5/16 YES 59 S98.6 EAST 33K 5500 7 3/4 7 3/16 YES 60 B-76 EAST 33K 5500 6 5 9/16 YES 61 S-12.6 EAST 33K 5500 7/8 7/8 YES 62 S-26 EAST 33K 5500 2 2 1/16 YES 63 S-26 EAST 33K 5500 2 2 3/16 YES 64 B-26 EAST 33K 5500 2 2 YES Equipment ID: Ram No: 93014 Pump No: 381996 Gauge No: 93014 Equipment Calibration Date: 7/29/98 Comments: Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (I) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibili~, for varianon in quality ~,compos~tion, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c::wpwin:.reports~D7429-24?-98~.ST October 12. 1998