ELONGATION REPORT
Project: Mansions By The Lake Page 1 of 4
Report No: 3137-D7429-278 Sample Date: October 8, 1998
Client: Western Rim Services Report Date: October 9, 1998
Location: Building # 1 Technician: R. Lovelady
# Tendon Location Jack Force Gauge Required Elongations Elongations Total Within
No. (Kips) Pressure Elongations End (I) End (2) Elongations To'.eranc¢
I S-59 North West 33K 5500 4 5;8 4 7/16 YES
2 B-59 North South 33K 5500 4 5/8 4 7/8 YES
3 S-68 North South 33K 5500 5 3/8 5 3/4 YES
4 S-96 North South 33K 5500 7 1/2 7 YES
5 S-98.6 North South 33K 5500 7 3/4 8 5/16 YES
6 S-98.6 North South 33K 5500 7 3/4 7 13/16 YES
7 B-73.6 North South 33K 5500 5 5/8 5 1/2 YES
8 S-100 North South 33K 5500 7 7/8 8 3/8 YES
9 S-100 North South 33K 5500 7 7/8 8 1/8 YES
10 S-100 North South 33K 5500 7 7/8 8 1/8 YES
11 17-73 North South 33K 5500 5 5/8 5 5/8 YES
12 S-96 North South 33K 5500 7 1/2 6 15/16 YES
13 S-96 North South 33K 5500 7 1/2 6 15/16 YES
14 S-96 North South 33K 5500 7 1/2 7 1/2 YES
15 S-96 North South 33K 5500 7 1/2 7 558 YES
16 S-98.6 North South 33K 5500 7 3/4 7 5i16 YES
17 B-71.6 North South 33K 5500 5 1/2 5 7."8 YES
18 $-98.6 North South 33K 5500 7 3/4 8 YES
19 S-98.6 North South 33K 5500 7 3;4 7 3;4 YES
Equipment ID: Ram No: 93014 Pump No: 381996 Gauge No: 93014
Equipment Calibration Date: 9/4/98
Comments:
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Mike Hodge; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The test results presented herein were prepared based upon the specific, samples provided for testing. We assume no
responsibility for variation in qnality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by
persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are
addressed.
c:',.wpwin".reports'..D7429-278-98',PW October 12, 1998
· '°' RoneEn ineers
Rone Engineers. Inc. ] ~, "- Goodmgh[ Lane TeL ~.~72j 24~-45;7
Oa,'as. For, Won', Dallas, Texas Metro (972) 263-i 555
75229 Fax (972) 241-5174
ELONGATION REPORT
Project: Mansions By The Lake Page 2 of 4
Report No: 3137-D7429-278 Sample Date: October 8, 1998
Client: Western Rim Services Report Date: October 12, 1998
Location: Building # 1 Technician: R. Lovelady
# Tendon Location Jack Force Gauge Required Elongations Elongations Total Within [
No. (Kips) Pressure Elongations End (1) End (2) Elongations Tolerance
20 S-98.6 North South 33K 5500 7 3/4 7 3/8 YES
21 B-76 North South 33K 5500 6 6 YES
29-. S-12.6 North South 33K __. 5500 7/8 1 YES
~ S-26 North South 33K 5500 2 2 YES
24 S-26 North South 33K 5500 2 2 I/4 YES
25 S-26 North South 33K 5500 2 2 YES
26 B-27 South East 33K 5500 2 1/8 I 15/16 YES
27 S-27 South North 33K 5500 2 1/8 1 15i16 YES
28 S-46 South North 33K 5500 3 5/8 3 3/4 YES
29 B-27 South North 33K 5500 2 1/8 2 YES
30 B-27 South North 33K 5500 2 1/8 2 1/4 YES
31 B-27 South North 33K 5500 2 1/8 2 1/4 YES
32 B-27 South North 33K 5500 2 1/8 2 YES
33 5-55 South North 33K 5500 4 1/4 3 15/16 YES
34 B-55 South North 33K 5500 4 1.,'4 4 3/8 YES
35 B-65.5 South North 33K 5500 5 1/8 5 1...'8 YES
36 $-60.6 North East 33K 5500 4 3;4 5 YES
37 $-59.6 East West 33K 5500 4 5/8 4 5/8 YES
38 S-59.6 East West 33K 5500 4 5/8 4 5/8 YES
Equipment iD: Ram No: 93014 Pump No: 381996 Gauge No: 93014
Equipment Calibration Date: 9/4/98
Cormnents:
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; Cit3,' of Coppell
(1) Mr. Mike Hodge; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LLMrrATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no
responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar su~ect matter provided by
persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom ~ey are
addressed.
c:',wpwin\reports\D7429-278-98:.PW October 12, 1998
RoneEn ineers
Bone Engineers. Inc. i ~, --' '. Goodn~gnt Lane lei. ~c~ ~-. 2_--1.1-45 ;-
Da,,as ~or:. 'A/oq~ Dallas. Texas Metro (972) 263-1555
75229 Fax {972) 241-5174
ELONGATION REPORT
Project: Mansions By The Lake Page 3 of 4
Report No: 3137-D7429-278 Sample Date: October 8, 1998
Client: Western Rim Services Report Date: October 12, 1998
Location: Building # 1 Technician: R. Lovelady
# Tendon Location Jack Fore Gauge Required Elongations Elongations Total Within
No. (Kips) Pressure Elongations End (1) End (2) Elongations Tolerance
39 B-59.6 East West 33K 5500 4 5/8 5 YES
40 S-59.6 East West 33K 5500 4 5/8 4 5/8 YES
41 S-62.6 East West 33K ~.. 5500 4 7/8 5 YES
42 S-62.9 East West 33K 5500 4 7/8 4 7/8 YES
43 B-62.9 East West 33K 5500 4 7/8 4 718 YES
44 S-59 East West 33K 5500 4 5i8 5 1/16 YES
45 S-59 East West 33K 5500 4 5/8 5 1/16 YES
46 $-61.6 East West 33K 5500 4 3/4 5 1/8 YES
47 B-61.6 East West 33K 5500 4 3/4 5 1/4 YES
48 $-61.6 East West 33K 5500 4 3/4 5 1/4 YES
49 $-59.6 East West 33K 5500 4 5/8 5 YES
50 S-61.6 East West 33K 5500 4 3/4 4 5/8 YES
51 S41.6 East West 33K 5500 4 3/4 5 1/4 YES
52 S-59.6 East West 33K 5500 4 5/8 5 1i8 YES
53 S-59.6 East West 33K 5500 4 5/8 4 7/8 YES
54 $-67 East x3,'est 33K 5500 5 1/4 4 15i16 YES
55 B-67 East x. Vest 33K 5500 5 1/4 5 1/2 YES
56 S-67 East West 33K 5500 5 1/4 5 1/2 YES
57 S-67 East West 33K 5500 5 1,:4 5 1/4 YES
Equipment ID: Ram No: 93014 Pump No: 381996 Gauge No: 93014
Equipment Calibration Date: 9/4/98
Comments:
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Sec'ices
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Mike Hodge; City, of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LLMrrATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no
responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by
persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom the3' are
addressed.
c:w,.pwin'..reports~,D7429-278-98~..pw October 12, 1998
I~one I~ngmeers, Inc. -, a.e RoneEnqineers
Ca,ms F-c,~ W'c-~ Dallas. Texas Metro (972) 263-1555
75229 Fax (972) 241-5174
ELONGATION REPORT
Project: Mansions By The Lake Page 4 of 4
Report No: 3137-D7429-278 Sample Date: October 8, 1998
Client: Western Rim Services Report Date: October 12, 1998
Location: Building # 1 Technician: R. Lovelady
# Tendon Location Jack Force Gauge Required Elongations Elongations Total Within
No. (Kips) Pressure Elongations End (1) End (2) Elongations Tolerance
58 S-67 East West 33K 5500 5 1/4 5 1/4 YES
59 B-67 East West 33K 5500 5 1/4 5 YES
60 S-67 East West 33K ~, 5500 5 1,'4 5 1/4 YES
61 $-67 East West 33K 5500 5 1i4 5 1/4 YES
62 S-59 East West 33K 5500 4 5/8 4 7/8 YES
63 $-29.6 East West 33K 5500 2 1/4 2 1/4 YES
64 B-29.6 East West 33K 5500 2 1/4 2 5/8 YES
Equipment ID: Ram No: 93014 Pump No: 381996 Gauge No: 93014
Equipment Calibration Date: 9/4/98
Comments:
Distribution:
(I) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; CiD' of Coppell
(i) Mr. Mike Hodge; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(i) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no
responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by
persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom lhey are
addressed.
c:X.wpwin~.reports\D7429-278-98'.PW October 12, 1998