Mansions Phase 1-LR 981003 (3) none Engineers. Inc. 117-' Goodn,ght Lane Tel. ¢72) - RoneEnqJneers
J
Da~as..~or:. Wcc. h Dallas. Texas Metro (972) 263-1555
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansions By The Lake Purchase Order
Number 3137-D7429-230 J Date of Observation 9/02/98 Report Date 10/03/98
To Western Rim Services
Location BUILDING //18, 15' WEST, 10' NORTH FROM SOUTHEAST CORNER OF BUILDING
Contractor
Supplier LATTIMORE J Plant 6 J Truck 941 Ticket 6079394
I
Time Sampled 11:15 Time Batched 10:35 Weather Condition CLEAR
Concrete Temperature (°F) 89 Ambient Temperature (°F) 89 Mix Number 61
Mix Description Unit Weight Water Added 10 GALLONS
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 5 1/2
ENTRAINED AIR (%) 4.5
Concrete Cylinder Test(s)
Specimen I Age I T., ~,. I To,.,,o.~ Compressive
No. (Days) (lbs.) Strength (psi) Strength Required (psi)
102A 7 9/09 64000 2260 3000/28 DAYS
B 28 9/30 85000 3010
C 28 9/30 85000 3010
D H
Curing Method I Test Method I Standard 6" x 12" I Engineer/Technician R. LOVELADY
ASTM C 31 I ASTM C 39_1 Area 28.27 sq. in.
I
Signature: Mike Fuller, (~U) Supervisor, CMT
Remarks and/or Distribution '--/'
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Mike Hedge; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no
respons~bdit,t for variabon ~n quality Icomposition, appearance, performance, etc. J or any other feature of similar subject matter provided by
persons or cCndltlO~5 over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are
addressed.