Mansions Phase 1-LR 981003 (4) Rone Engineers. Inc. l lLa.e' (97= 24 .-45 7 -- RoneEn_qineers
Da.las.-Fo.. Wcqh. Dallas. Texas Metro (972) 263-1555
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansions By The Lake Purchase Order
Number 3137-D7429-256 Date of Observation 9/24/98 Report Date 10/03/98
To Western Rim Services
Contractor
Supplier LATTIMORE I Plant 7 I Truck 785 I Ticket 7058940
Location BUILDING SLAB #30, 30' SOUTH AND 12' WEST OF NORTHEAST CORNER OF BUILDING
Time Sampled 8:40 AM Time Batched 7:52 AM Weather Condition CLEAR
Concrete Temperature (°F) 88 Ambient Temperature (°F) 84 Mix Number 51
Mix Description Unit Weight Water Added NONE
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 4.0
Concrete Cylinder Test(s)
No. (Days) (lbs.) Strength (psi) Strength Required (psi)
113A 7 10/01 73000 2580 3000/28 DAYS
B 28 10/22
C 28 10/22
D H
Engineer/Technician
G.
BEALL
ASTM C 31 I ASTM C 39 ,,[, Area 28.27 sq. in. I
~iegmn~tr~e~n~,iokreD~ltlr~,utAi~n-i' ~Supervisor,-- CMT
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Mike Hodge; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The test results presented herein were prepared oased upon the specific samples provided for testing. We assume no
responsibility for variation in quality icom~os~t~on, appearance, performance, etc..., or any other feature of simdar subject matter provided by
persons or conditions over w'h;ch we have no control. Our 'etters and reoorts are 'or the exclusive use of the clients to whom they are
adcressed.
c:'.wpwin'.reports'.D7429-256-98tST October 3, 1998