Loading...
Mansions Phase 1-LR 981003 (6) Da~.as, Fo,1 Wod~ Dallas. Texas Metro (972) 263-155~ 75229 Fax (972) 241-5174 Concrete Cylinder Test Report Project Mansions By The Lake Purchase Order Number 3137-D7429-257 [ Date of Observation 9/24/98 Report Date 10/03/98 To Western Rim Services Contractor Supplier LATTIMORE I Plant 7 I Truck 610 I Ticket 7058947 Location BUILDING SLAB #30, 24' WEST AND 1 $' SOUTH OF NORTHEAST CORNER OF BUILDING Time Sampled 9:20 AM Time Batched 8:32 AM Weather Condition CLEAR Concrete Temperature (°F) 88 Ambient Temperature (°F) 84 Mix Number 51 Mix Description Unit Weight Water Added NONE Physical Data ACTUAL SPECIFICATIONS SLUMP (in.) 6 1/2 Concrete Cylinder Test(s) Specimen I Age I Test Date l TOtal Load Compressive No. (Days) (lbs,) Strength (psi) Strength Required (psi) 114A 7 10/01 83000 2940 3000/28 DAYS B 28 10/22 83000 2940' C 28 1 0/22 86000 3060 D 56 11/20 Mike Fuller, AET Supervisor, CMT Signature: Remarks and/or Distribution *DID NOT MEET REQUIRED STRENGTH, WILL TEST HOLD CYLINDER AT 56 DAY BREAK Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein 'were prepared based upon the specific samples provided for testing. We assume qo responsibility for variation ~n quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:'.wpwin,.reports~D7429-257-98'.ST October 3, 1998