Mansions Phase 1-LR 981003 (7) Dadas, Fo~ Wo,lr' Dallas. Texas Metro (972) 263-1555
75229 Fax ,'a72i 241-5174
Concrete Cylinder Test Report
Project Mansions By The Lake Purchase Order
Number 3137-D7429-256 I Date of Observation 9/24/98 Repor~ Date 10/03/98
To Western Rim Services
Contractor
Supplier LATTIMORE Plant 7 I Truck 785 I Ticket 7058940
Location BUILDING SLAB//30, 30' SOUTH AND 12' WEST OF NORTHEAST CORNER OF BUILDING
Time Sampled 8:40 AM Time Batched 7:52 AM Weather Condition CLEAR
Concrete Temperature (°F) 88 Ambient Temperature I°F) 84 Mix Number 51
Mix Description Unit Weight Water Added NONE
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 4.0
Concrete Cylinder Test(s)
No. (Days) (lbs.) Strength (psi) Strength Required (psi)
113A 7 10/01 73000 2580 3000/28 DAYS
B 28 10/22 106000 3750
C 28 10/22 104500 3700
D H
ASTM C 31 ASTM C 39 Area 28.27 sq. in.
Signature: Mike Fuller, AET Supervisor, CMT
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Mike Hedge; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS; The test results presented herein were prepared based upon the specific samples prowded for Jesting. We assume co