Loading...
Mansions Phase 1-LR 981001 (3) Rone Engineers, Inc. 11 2- C~oodn~gnl Lane- Yel. (972)£41-45'17- RoneEn ineers Dal,as/Fo~ Wo~h Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansions By The Lake Page 1 of 1 Report No: 3137-D7429-259 Sample Date: September 28, 1998 Client: Western Rim Services Report Date: October 1, 1998 Location: Builidng 40 Technician: R. Lovelady # Tendon Location Jack Force Gauge Required Elongations Elongations Total Within No. (Kips) Pressure Elongations End (1) End (2) Elongations Tolerance i S-27 North Side 33K 5500 2 1/8 ...... 0 West Corner 2 S-27 North Side 33K 5500 2 1/8 .... 0 West Corner 3 B-27 NorUh Side 33K 5500 2 1/8 ...... 0 West Corner 4 S-48 *South Side 33K 5500 3 5/8 ....... 5 6 7 8 9 10 11 12 13 14 15 Equipment ID: Ram No: 94016 Pump No: 380794 Gauge No: 94016 Equipment Calibration Date: 8/24/98 Comments: *S-48 A/C Pad in the way (has concrete poured). S-27, S-27, B-27 pulled to 4500 PSI, 80% of 5500 did not get any elongation. Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by /% persons or conditions over which we have no conn'ol. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:\wpwin',reports\D7429-259-98\ST October 1, 1998 ~