Loading...
Mansions Phase 1-LR 980929 Rone Engineers. Inc. 112' 3oodnight Lane Tel. (972) 241-4517 RoneEn_qineers Oai,as.-Fo.'1 Wo.ln Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansions By The Lake Page I of 4 Report No: 3137-D7429-247 Sample Date: September 17, 1998 Client: Western Rim Services Report Date: September 29, 1998 Location: Building 20 Technician: R. Lovelady # Tendon Location Jack Force Gauge Required Elongations Elongations Total Within No. (Kips) Pressure Elongations End (1) End (2) Elongations Tolerance I S-29 SW Corner 33K 5500 2 1/4 2 1/4 YES 2 B-29 WEST 33K 5500 2 1/4 2 1/8 YES 3 S-48 WEST 33K 5500 3 3/4 3 3/4 YES 4 B-30 WEST 33K 5500 2 3/8 2 NO 5 B-30 WEST 33K 5500 2 3/8 2 NO 6 B-30 WEST 33K 5500 2 3/8 2 NO 7 B-30 WEST 33K 5500 2 3/8 2 3/16 YES 8 S-57 SE Corner 33K 5500 4 1/2 4 1/4 YES 9 B-57 SOUTH 33K 5500 4 1/2 4 3/16 YES 10 B-78 SOUTH 33K 5500 6 1/8 4 7/8 NO 11 S-63 SOUTH 33K 5500 4 7/8 4 3/8 NO 12 S-62 SOUTH 33K 5500 4 7/8 5 YES 13 B-62 SOUTH 33K 5500 4 7/8 4 9/16 YES 14 S-62 $OLrrH 33K 5500 4 7/8 4 5/8 YES 15 S-62 SOD'I'll 33K 5500 4 7/8 4 5/8 YES 16 S-65 SOUTH 33K 5500 5 1/8 4 7/8 YES 17 S-65 SOUTH 33K 5500 5 1/8 5 3/16 YES 18 B-65 SOUTH 33K 5500 5 1/8 4 13/16 YES 19 S-61 SOUTH 33K 5500 4 3/4 4 3/4 YES Equipment ID: Ram No: 93014 Pump No: 381996 Gauge No: 93014 Equipment Calibration Date: 7/29/98 Comments: Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppell (I) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing, We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are ~ addressed. c:\wpwin\reports\D7429-24?-98\ST September 29. 1998 Rone Engineers, Inc. 112 3oodnight Lane Tel. (972) 241-4517 Rone Engineers Da,!as.-Fo~ ¢,/or~.~ Dallas. Texas Metro (972) 263-1555 ~~ , 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansions By The Lake Page 2 of 4 Report No: 3137-D7429-247 Sample Date: September 17, 1998 Client: Western Rim Services Report DaM: September 29, 1998 Location: Building 20 Technician: R. Lovelady # Tendon Location Jack Force Gauge Required Elongations Elongations Total Wifffin No. (Kips) Pressure Elongations End (1) End (2) Elongations Tolerance 20 S-61 SOUTH 33K 5500 4 3/4 4 5/8 YES 21 S-64 SOUTH 33K 5500 5 4 9/16 NO 22 B-64 SOUTH 33K 5500 5 5 1/4 YES 23 S-64 SOLrr H 33K 5500 5 5 1/8 YES 24 S-62 SOUTH 33K 5500 4 718 4 7/8 YES 25 S-64 SOUTH 33K 5500 5 4 5/8 NO 26 B-64 SOLrrH 33K 5500 5 4 1/2 NO 27 S-62 SOUTH 33K 5500 4 7/8 4 3/4 YES 28 S-62 SOUTH 33K 5500 4 7/8 4 3/4 YES 29 S-~9 SOUTH 33K 5500 5 3/8 5 112 YES 30 B-69 SOUTH 33K 5500 5 3/8 5 3/$ YES 31 S--69 SOUTH 33K 5500 5 3/8 5 7/16 YES 32 $-69 SOUTH 33K 5500 5 3/8 5 3/8 YES 33 S-69 SOUTH 33K 5500 5 3/8 5 1/4 YES 34 B-69 SOUTH 33K 5500 5 3/8 5 3/4 YES 35 $-69 $OL~rH 33K 5500 5 3/8 5 3/8 YES 36 S-69 SOUTH 33K 5500 5 3/8 5 3/16 YES 37 S-61 SOL'TH 33K 5500 4 3/4 4 7/16 YES 38 S-32 SOUTH 33K 5500 2 1/2 2 1/4 NO Equipment ID: Ram No: 93014 Pump No: 381996 Gauge No: 93014 Equipmem Calibration Date: 7/29/98 Comments: Distribution: (l) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibilio' for variation in quality' (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:\w~pwin\reports\D7429-2¢7-98\ST September 29, 1998 ,c~ m 241-4517 ' Rone Engineers, Inc. 112 3oodnight Lane .-'el. ~,,.,7~-, RoneEn Da,las. Fort VVo"th Dallas. Texas Metro (972) 263-!555 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansions By The Lake Page 3 of 4 Report No: 3137-D7429-247 Sample Date: September 17, 1998 Client: Western Rim Services Report Date: September 29, 1998 Location: Building 20 Technician: R. Lovelady # Tendon Location Jack Force Gauge Required Elongations Elongations Total Within No. (Kips) Pressure Elongations End (1) End (2) Elongations Tolerance 39 B-32 WEST 33K 5500 2 1/2 2 1/8 NO 40 S-61 NECorner 33K 5500 4 3/4 4 15/16 YES 41 B-61 EAST 33K 5500 4 3/4 4 1/2 YES 42 S-70 EAST 33K 5500 5 7/16' 5 1/4 YES 43 S-98 EAST 33K 5500 7 5/8 7 1/2 YES 44 S-101 EAST 33K 5500 7 7/8 7 5/8 YES 45 S-101 EAST 33K 5500 7 7/8 7 1/4 NO 46 B-75 EAST 33K 5500 5 7/8 5 NO 47 S-102 EAST 33K 5500 8 7 1/2 YES 48 S-102 EAST 33K 5500 8 7 7/16 YES 49 S-102 EAST 33K 5500 8 7 3/4 YES 50 B-76 EAST 33K 5500 6 4 3/4 NO 51 S-98 EAST 33K 5500 7 5/8 7 1/4 YES 52 S-98 EAST 33K 5500 7 5/8 7 9/16 YES 53 S-98 EAST 33K 5500 7 5/8 7 3/8 YES 54 S-98 EAST 33K 5500 7 5/8 7 NO 55 S-101 EAST 33K 5500 7 7/8 7 1/16 NO 56 B-74 EAST 33K 5500 5 3/4 4 9/16 NO 57 S-101 EAST 33K 5500 7 7/8 5 7/8 NO Equipment ID: Ram No: 93014 Pump No: 381996 Gauge No: 93014 Equipment Calibration Date: 7/29/98 Comments: *Elongation from table. Technician did interpolation between 69 & 71 to get elongation for 70. Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (I) Mr. Larry Davis; City of Coppell (I) Mr. Mike Hodge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:',wpwin\reports\D7429-247-98\ST September 29, 1998 Rone Engineers. Inc. 112 3oodn,ght Lane :i Tei. (972) 241-45i7 RoneEnc, ineers i Da,las. For1 '¢,~o"t.;" Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansions By The Lake Page 4 of 4 Report No: 3137-D7429-247 Sample Date: September 17, 1998 Client: Western Rim Services Report Date: September 29, 1998 Location: Building 20 Technician: R. Lovelady # Tendon Location Jack Force Gauge Required Elongations Elongations Total Within No. (Kips) Pressure Elongations End (1) End (2) Elongations Tolerance 58 S-101 EAST 33K 5500 7 7/8 7 5/16 YES 59 S-101 EAST 33K 5500 7 7/8 7 1/16 NO 60 B-79 EAST 33K 5500 6 1/8 5 5/16 NO 61 S-15 EAST 33K 5500 I 1/8 3/4 NO 62 S-27 EAST 33K 5500 2 1/8 2 1/16 YES 63 S-27 EAST 33K 5500 2 1/8 2 3/16 YES 64 B-27 EAST 33K 5500 2 1/8 2 YES Equipment ID: Ram No: 93014 Pump No: 381996 Gauge No: 93014 Equipment Calibration Date: 7/29/98 Comments: Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LLMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility, for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:\wpwin\reporcs\D7429-247-98\ST September 29, 1998