Dry Clean & Donut-CS010709 (2) QAgH ~:LLV[O-60-£O
BENTLEY ENGINEERING, INC.
CIVIL ENGINEERING · PLANNING
CONSTRUCTION MANAGEMENT
MARC O. BENTLEY, P.E.
July 9, 2001
Mr. Kenneth M. Griffin, P.E.
Director of Engineering & Public Works
City of Coppell
255 Parkway
Coppell, Texas 75019
Re: Dry Clean City
Dear Mr. Griffin:
Attached is one (1) City mark-up and two (2) revised sets of the site development plans
for the referenced project. We have revised these plans in accordance with your letter
dated July 5, 2001.
In accordance with Item 3 of your letter, we are proposing that the on-site pavement be 6
inch thick 4000 PSI reinforced concrete pavement with #3 rebar on 18 inch centers in
both directions on 6 inch compacted subgrade. This request is being made in lieu of lime
stabilizing the subgrade.
We would appreciate your consideration of our alternate paving section. If you should
have any questions or concerns, please do not hesitate to call.
Sincerely,
BENTLEY ENGINEERING, INC.
Marc O. Bentloy, F'.E.
Attachments
702 GATEWOOD DRIVE GARLAND, TEXAS 75043 (972) 240-4821 FAX (972) 240-0922