Connell Skaggs (7-11)-CS 900507 GINN, INC. CONSULTING ENGINEERS ~/~:[,z~ i:mV'rEW v..~ot~,xt,,mmt ;:( -' NAY- 81ggo Date: Ma 7, 1990 _ To: City of Coppell Public Works Department From: ~hn C. Karlsruher, P.E. Re: R_~v4cw ~.~nn~.~ for the Engineering Plans for the ~ Mobil/7-11 Join~ %~cnt:lre on Denton Tap Road and Salld~ Lake Road We have performed a final review of these plans with the Public Works Department Section Heads and have only the following comments: 1. A note indicating that a 6" lime stabilized subgrade will be required in all paved areas should be added to the Grading Plan. 2. A note indicating that the 6" fire hydrant lead crossing Sandy Lake Road must be installed by the dry bore method. No open cut will be allowed crossing Sandy Lake Road. 3. There is a notation on the Site Plan indicating a "NEW LOCATION OF FIRE LANE EASEMENT". This may require some kind of Plat Amendment. By copy of this memo we request input from the Planning Department. Once the above comments have been addressed, these plans need to be resubmitted by the Engineer for approval. Three sets of approved plans will be retained by the Public Works Department. cc: Gary Sieb Taryon Bowman Mostata Setayesh, P.E. - The Dimension Group, Inc. 17103 Preston Road · Suite 100 · LB 118 · Dallas, Texas 75248 · Phone 214/248-4900