WA9302-LR 951016 (2) F'~'EOTECHNICAL
E GEE Consultants, Inc.
E
iNVIRONMENTAL
2540 Glenda Lane · Suite 108 · Dallas, Texas 75229 · (214) 620-9791 · Fax (214) 620-9794
REPORT OF CONCRETE MIX INSPECTION
Report Date: October 16, 1995 Date Concrete Placed: September 15, 1995 Standard 6"x12"
Client: City of Coppell Area 28.27 Square Inches
Project: 6.0 Million Gallon Water Storage Tank Concrete ReportNo.: 11
Contractor: Natgun Construction Pr0]ect No.: 95 - 0196
Concrete Supplier and Plant: RediMix Concrete Plant #1
Location of Placement: Pier D- 13
}~l.t~~' R TAT' S Source/ Batch Wts.
Description (lbs./0.075 C.Y) "F~SP~.C~I"O~ DATA
Mix Number: 686 Time Sample Bateheal: 8:39 am
Cement: Time Sampled: 9:15 am
Fly Ash: Sample Location: Pier D-13
Truck/Ticket No: 192/10512
Coarse Aggregate: Temperature:
Intermediate Aggregate: Ambient Range: 75°F
Fine Aggregate: Concrete Range: 80°F
Admixtures: Slump Range (inches): 41/2''
Weather Conditions: Sunny
1 Air Time Started: 9:00 am
2 Time Completed: 9:30 am
Added Water: 8 gal. Sample Air Content (%): No Test
Total Cubic Yards Placed: 8.0 C.Y.
Required Strength (Lbs./sq.in.): 4,000
specimen Measured Age Date Total Load Compresslye Strength
Remarks
Number Slump (in.) (Days) Tested (Lbs.) (Lbs./Sq.ln.)
CWT 45 4~" 7 09/22/95 146,540 5,180
CWT 46 4~" 7 09/22/95 132,360 4,680
CWT 47 4x~'' 28 10/13/95 158,520 5,610
CWT 48 4~" 28 10/13/95 159,180 5,630
Test Methods Utilized Fracture Regular
ASTM C-31,C-39,C-143 (Unless Noted Otherwise) Cylindem Made By: P.Chen
Remarks and/or Distribution:
cc: Mr. Larry Davis - City of Coppell
Mr. Bob Barbarisi, Jr. - Natgun Corporation
Mr. Gary Hendricks - Shimek, Jacobs and Finklea
Mr. Gary Herron - RediMix Concrete ~i
GEE Consultants° Inc. Reviewed by: