Mansions Phase 1-LR 980925 (2) Rone Engineers. ..... Inc. 1127'-Goodnight Lane Tel. ;aT~-,/ 241-4517 - RoneEngineers
i D~Jas. ~o~. W'c.~h Dallas. Texas Metro (972) 263-1555 W~
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansions By The Lake Purchase Order
Number 3137-D7429-226 J Date of Observation 8/27/98 Report Date 09/25/98
To Western Rim Services
Location TENNIS COURT - - 20' NORTH BY 20' WEST FROM SOUTHEAST CORNER
Contractor
Supplier LATTIMORE J Plant 6 J Truck 615 Ticket 6079093
I
I
Time Sampled 10:20 Time Batched 9:35 Weather Condition CLEAR
Concrete Temperature (°F) 94 Ambient Temperature I°F) 93 Mix Number 61
Mix Description Unit Weight Water Added 10 GALLONS
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 6 1/2
ENTRAINED AIR (%) 4.5
Concrete Cylinder Test(s)
Specimen J Age J Test Date J Total Load J Compressive
No. (Days) (lbs.) Strength (psi) Strength Required (psi)
IOOA 7 9/03 66000 2330 3000/28 DAYS
B 28 9/24 99000 3500
C 2_8 9/24 99000 3500
D H
I
Curing Method Test Method Standard 6" x 12" ~ Engineer/Technician J. BOSTER
ASTM C 31 ASTM C 39 Area 28.27 sq. in.
i
Signature: Mike Fuller, Supervisor, CMT ~"
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Mike Hodge; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The test results presented hereto were prepared based upon the specific samples provided for testing. We assume no
responsibility for vanation in quality (composition, appearance, performance, etc.) or any other feature of s~mdar subject matter provided by
persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clier{ts to whom they are
addressed.
c:~wpwimreports\D7429-226-98\ST September 25, 1998