Loading...
Mansions Phase 1-LR 980924 Rone Engineers, Inc. 112~ ',oodnight Lane Tei. (972) 24!-4517 RoneEnqineers Da!las/Foal Worth Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansions By The Lake Page 1 of 4 Report No: 3137-D7429-247 Sample Date: September 17, 1998 Client: Western Rim Services Report Date: September 24, 1998 Location: Building//21 Technician: R. Lovelady # Tendon Location Jack Force Gauge Required Elongations Elongations Total Within No. (Kips) Pressure Elongations End (1) End (2) Elongations Tolerance 1 S-29 N E Side 33K 5500 2 1/4 2 1/4 YES 2 b-29 East-West 33K 5500 2 1/4 2 1/16 YES 3 S-48 East-West 33K 5500 3 3/4 3 1/2 NO 4 B-30 East-West 33K 5500 2 3/8 2 NO 5 B-30 East-West 33K 5500 2 3/8 2 1/8 NO 6 B-30 Enst-West 33K 5500 2 3/8 2 NO 7 B-30 East-West 33K 5500 2 3/8 2 NO 8 S-57 N W Side 33K 5500 4 1/2 4 3/8 YES 9 B-57 North-South 33K 5500 4 1/2 4 NO 10 B-78 North-South 33K 5500 6 I/8 5 I/4 NO 11 S-63 North-Sou~h 33K 5500 4 7/8 4 7/8 YES 12 S-62 North-South 33K 5500 4 7/8 4 5/8 YES 13 B-62 North-South 33K 5500 4 7/8 4 11/16 YES 14 S-62 North-South 33K 5500 4 7/8 4 7/16 YES 15 S-62 North-South 33K 5500 4 7/8 5 1/16 YES 16 S-65 North-South 33K 5500 5 1/8 5 YES 17 S-65 North-South 33K 5500 5 118 4 15/16 YES 18 B-65 North-South 33K 5500 5 1/8 4 3/4 YES 19 S-61 North-South 33K 5500 4 314 4 7/8 YES Equipment ID: Ram No: 93014 Pump No: 381996 Gauge No: 93014 Equipment Calibration Date: 7/29/98 Comments: Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matu~r provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clie.nts to whom they are fx addressed. ~ c:\w~win\reports\D7429-247-98\ST September 24, 1998 Rone Engineers, Inc. 112~ -~oodnight Lane Tel. (972) 241-4517 Rone Engineers Dalias.-'l=or:, Worth Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansions By The Lake Page 2 of 4 Report No: 3137-D7429-247 Sample Date: September 17, 1998 Client: Western Rim Services Report Date: September 24, 1998 Location: Building//21 Technician: R. Lovelady # Tendon Location Jack Force Gauge Required Elongations Elongations Total Within No. (Kips) Pressure Elongations End (1) End (2) Elongations Tolerance 20 S-61 33K 5500 4 3/4 4 I/2 YES 21 $-64 33K 5500 5 4 7/8 YES 22 B-64 33K 5500 5 4 3/4 YES 23 S-64 33K 5500 5 4 1/4 NO 24 S-62 33K 5500 4 7/8 5 1/16 YES 25 S-64 33K 5500 5 4 5/8 NO 26 B-64 33K 5500 5 4 7/8 YES 27 S-62 33K 5500 4 7/8 4 3/4 YES 28 S-62 33K 5500 4 7/8 5 YES 29 S-69 33K 5500 5 3/8 5 3/8 YES 30 B-69 33K 5500 5 3/8 5 YES 31 S-69 33K 5500 5 3/8 5 1/4 YES 32 S-69 33K 5500 5 3/8 5 7/16 YES 33 S-69 33K 5500 5 3/8 5 YES 34 B-69 33K 5500 5 3/8 5 YES 35 S-69 33K 5500 5 3/8 5 3/8 YES 36 S-69 33K 5500 5 3/8 5 3/16 YES 37 S-61 33K 5500 4 3/4 4 3/4 YES 38 S-32 33K 5500 2 I/2 2 t/4 NO Equipment ID: Ram No: 93014 Pump No: 381996 Gauge No: 93014 Equipment Calibration Date: 7/29/98 Comments: Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the cliellts to whom they are addressed. c:\wpwin\reports\D7429-247-98\ST September 24, 1998 Rune Engineers, Inc. 112 3oodnight Lane Tel. (972) 241-4517 RoneEnc ineers Dal~as..-Fo~ Wccn Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansions By The Lake Page 3 of 4 Report No: 3137-D7429-247 Sample Date: September 17, 1998 Client: Western Rim Services Report Date: September 24, 1998 Location: Building//21 Technician: R. Lovelady # Tendon Location Jack Force Gauge Required Elongations Elongations Total Within No. (Kips) Pressure Elongations End (1) End (2) Elongations Tolerance 39 B-32 33K 5500 2 1/2 2 3/8 YES 40 5-61 S W Corner 33K 5500 4 314 4 3/4 YES 41 B-61 West-East 33K 5500 4 3/4 4 3/4 YES 42 S-20 West-East 33K 5500 5 7/16' 4 7/8 NO 43 S-98 West-East 33K 5500 7 5/8 6 7/8 NO 44 S-101 West-East 33K 5500 7 7/8 6 7/8 NO 45 S-101 West-East 33K 5500 7 7/8 7 7/16 TES 46 B-75 West-East 33K 5500 5 7/8 5 3/4 YES 47 S-102 West-East 33K 5500 8 6 1/2 NO 48 S-102 West-East 33K 5500 8 7 1/2 YES 49 S-102 West-East 33K 5500 8 7 5/16 YES 50 B-76 West-East 33K 5500 6 5 11/16 YES 51 S-98 West-East 33K 5500 7 5/8 7 3/16 YES 52 S-98 West-East 33K 5500 7 5/8 7 11/16 YES 53 S-98 West-East 33K 5500 7 5/8 7 1/2 YES 54 S-98 West-East 33K 5500 7 5/8 7 1/2 YES 55 S-101 West-East 33K 5500 7 7/8 6 5/8 NO 56 B-94 West-East 33K 5500 5 3/8 5 1/4 YES 57 S-101 West-East 33K 5500 7 7/8 7 NO Equipment ID: Ram No: 93014 Pump No: 381996 Gauge No: 93014 Equipment Calibration Date: 7/29/98 Comments: *Elongaton from table. Technician did not interpolation between 69 and 71 to get elongation for 70. Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppell (I) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:\wpwin\reports\D7429-247-98~ST September 24, 1998 Rbne Engineers, Inc. 112' '3oodnight Lane Tel. (972) 241-4517 RoneEnc ineers Dallas.-'Fort Worth Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansions By The Lake Page 4 of 4 Report No: 3137-D7429-247 Sample Date: September 17, 1998 Client: Western Rim Services Report Date: September 24, 1998 Location: Building//21 Technician: R. Lovelady # Tendon Location Jack Force Gauge Required Elongations Elongations Total Within No. (Kips) Pressure Elongations End (1) End (2) Elongations Tolerance 58 S-101 33K 5500 7 7/8 7 3/8 YES 59 S-101 33K 5500 7 7/8 7 1/2 YES 60 B-79 33K 5500 6 I/8 5 NO 61 S-15 33K 5500 I 1/8 3/4 NO 62 S-27 33K 5500 2 1/8 2 1/8 YES 63 S-27 33K 5500 2 1/8 2 1/8 YES 64 B-27 33K 5500 2 1/8 2 YES Equipment ID: Ram No: 93014 Pump No: 381996 Gauge No: 93014 Equipment Calibration Date: 7/29/98 Comments: Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variaUon in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:',wpwin\reports\D7429-247~98\ST September 24, 1998