Loading...
Mansions Phase 1-LR 980921 i Rone Engineers, Inc. : 1123~--~oodnight Lane Tel. (972) 241-4517 - ineers Dallas~-Fort Wortl~ Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 Concrete Cylinder Test Report Project Mansions By The Lake Purchase Order Number 3137-D7429-242 I Date of Observation 9/11/98 Report Date 09/21/98 To Western Rim Services Contractor Supplier LATTIMORE Plant 6 ITruck804 I Ticket 6080078 Location SLAB ON GRADE, BUILDING #20 - 20' NORTH BY 10' WEST FROM SOUTHEAST CORNER Time Sampled N/A Time Batch 6:00 Weather Condition CLOUDY Concrete Temperature (°F) 88 Ambient Temperature (°FI N/A Mix Number 51 Mix Description Unit Weight Water Added NONE Physical Data ACTUAL SPECIFICATIONS SLUMP (in.) 5.0 ENTRAINED AIR (%) 5.0 Concrete Cylinder Test(s) SpecimenI Age I Test Date I Tota, ,oad I Compre,,,ve No. (Days) (lbs.) Strength (psi) Strength Required (psi) 107A 7 9/18 76000 2690 3000/28 DAYS B 28 10/9 C 28 10/9 D H ASTM C 31 ASTM C 39 Area 28.27 sq. in. Signature: Mike Fuller, AET ~j~ Supervisor, CMT Remarks and/or Distribution Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction .Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.J or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:\wpwin~reports\D7429-242-98\ST September 21, 1998