Mansions Phase 1-LR 980917 Rone Engineers, Inc. 11 ~ 3oodni(~ht_ Lane Tel. ~_~,,aTc, 241-4517 RoneEngineers
Dallas. Forl Worth Dallas. Texas Metro (972) 263-1555
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansions By The Lake Purchase Order
Number 3137-D7429-237 Date of Observation 9/09/98 Report Date 09/17/98
To Western Rim Services
Contractor
Supplier LATTIMORE Plant 7 I Truck 602 I Ticket 7058143
Location SLAB ON GRADE, BUILDING //21 - 30' SOUTH AND 10' EAST OFF NORTHWEST CORNER
Time Sampled 8:39 Time Batch 8:26 Weather Condition CLEAR
Concrete Temperature (OF) 88 Ambient Temperature (°F) 84 Mix Number 51
Mix Description Unit Weight Water Added 10 GALLONS
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 6 1/2
Concrete Cylinder Test(s)
No. (Days) Test Date (lbs.) Strength (psi) Strength Required (psi)
105A 7 9/16 66000 2330 3000/28 DAYS
B 28 10/7
C 28 10/7
D H
ASTM C 31 ASTM C 39 Area 28.27 sq. in.
Signature: Mike Fuller, AET ~ Supervisor, CMT
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Mike Hodge; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no
responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by
persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are
addressed.
c:'.wpwimreports~.D7429-237-98;ST September 17, 1998