Mansions Phase 1-LR 980917 (2) Rone Engineers. Inc. 112 Goodni_ght Lane Te,. (972) 241-4517 Rone En( ineers
Oa',as Fo~ Won:n Dallas. Texas Metro (972) 263-i 555
75229 Fax ~'a72; 241-5174
Concrete Cylinder Test Report
Project Mansions By The Lake Purchase Order
Number 3137-D7429-238 [ Date of Observation 9/09/98 Report Date 09i17i98
To Western Rim Services
Contractor
Supplier LATTIMORE J Plant 7 I Truck 757 I Ticket 7058147
Location SLAB ON GRADE, BUILDING //21 - 10' NORTH AND 30' WEST OFF SOUTHEAST CORNER
Time Sampled 9:30 Time Batch 9:12 Weather Condition CLEAR
Concrete Temperature (°F) 88 Ambient Temperature {OF) 88 Mix Number 51
Mix Description Unit Weight Water Added 10 GALLONS
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 5.0
Concrete Cylinder Test(s)
No. (Days) Test Date (lbs.) Strength (psi) Strength Required (psi)
106A 7 9/16 77000 2720 3000/28 DAYS
B 28 10/7
C 28 10/7
D H
Curing Method I Test Method / Standard 6" x12" I Engineer/TechnicianK. Mustafa
ASTM C 31 ASTM C 39 h Area 28.27 sq. in.
Signature: Mike Fuller, AET ~Supervisor, CMT
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Mike Hedge; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no
responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter prowded by
persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to 'whom they are
addressed.
c:'.wpwm',reports',D7429-238-98\ST September 17, 1998