Mansions Phase 1-LR 980903 (3) Rone Engineers, Inc. 1 ~2~ Goodn.ght Lane Tei. ~, 241- .517. - RoneEnqineers
Dallas/For[ ',,"v'c~n Dallas. Texas Metro (972) 263-1555
, 75229 Fax (972) 241-517,~
Concrete Cylinder Test Report
Project Mansions By The Lake Purchase Order
Number 3137-D7429-226 Date of Observation 8/27/98 Report Date 09/03/98
To Western Rim Services
Location TENNIS COURT - - 20' NORTH BY 20' WEST FROM SOUTHEAST CORNER
Contractor
Supplier LATTIMORE Plant 6 J Truck 615 Ticket 6079093
Time Sampled 10:20 Time Batched 9:35 Weather Condition CLEAR
Concrete Temperature (°F) 94 Ambient Temperature (°F) 93 Mix Number 61
Mix Description Unit Weight Water Added 10 GALLONS
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 6 1/2
ENTRAINED AIR (%) 4.5
Concrete Cylinder Test(s)
Specimen I AgeI ITotalLoad I Compressive
No. (Days) Test Date (lbs.) Strength (psi) Strength Required (psi)
IOOA 7 9/03 66000 2330 3000/28 DAYS
B 28 9/24
C 28 9/24
D H
Curing Method Test Method I Standard 6" x 12" Engineer/Technician J. BOSTER
ASTM C 31 ASTM C 39.t~ Area 28.27 sq. in.
Signature: Mike Fuller, ~ Supervisor, CMT
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Mike Hodge; City of Coppell
(1) Mr, Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The test results presented herein were prepared based upon the specific samples prowded for testing. We assume no
responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of simdar subject matter provided by
persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are
addressed.
c:;.wpwin',reports'.D7429-226-98',ST September 3, 1998