Loading...
Mansions Phase 1-LR 980903 (3) Rone Engineers, Inc. 1 ~2~ Goodn.ght Lane Tei. ~, 241- .517. - RoneEnqineers Dallas/For[ ',,"v'c~n Dallas. Texas Metro (972) 263-1555 , 75229 Fax (972) 241-517,~ Concrete Cylinder Test Report Project Mansions By The Lake Purchase Order Number 3137-D7429-226 Date of Observation 8/27/98 Report Date 09/03/98 To Western Rim Services Location TENNIS COURT - - 20' NORTH BY 20' WEST FROM SOUTHEAST CORNER Contractor Supplier LATTIMORE Plant 6 J Truck 615 Ticket 6079093 Time Sampled 10:20 Time Batched 9:35 Weather Condition CLEAR Concrete Temperature (°F) 94 Ambient Temperature (°F) 93 Mix Number 61 Mix Description Unit Weight Water Added 10 GALLONS Physical Data ACTUAL SPECIFICATIONS SLUMP (in.) 6 1/2 ENTRAINED AIR (%) 4.5 Concrete Cylinder Test(s) Specimen I AgeI ITotalLoad I Compressive No. (Days) Test Date (lbs.) Strength (psi) Strength Required (psi) IOOA 7 9/03 66000 2330 3000/28 DAYS B 28 9/24 C 28 9/24 D H Curing Method Test Method I Standard 6" x 12" Engineer/Technician J. BOSTER ASTM C 31 ASTM C 39.t~ Area 28.27 sq. in. Signature: Mike Fuller, ~ Supervisor, CMT Remarks and/or Distribution Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppell (1) Mr, Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples prowded for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of simdar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:;.wpwin',reports'.D7429-226-98',ST September 3, 1998