WA9302-LR 951011 (7) 'EOTECHN ICAL
E I GEE Consultants, Inc.
E
~NVIRONMENTAL
2540 Glenda Lane · Suite 108 · Dallas, Texas 75229 · ' (214) 620-9791 · Fax (214) 620-9794
REPORT OF CONCRETE MIX DESIGN
Report Date: October 11, 1995 Date Concrete Placed: September 29, ]-995 Standard 6"x12"
Client: City of Coppoll Area 28.27 Square Inches
Project: 6.0 Million Gallon Water Storage Tank Concrete Repo~ No.: 1
Contractor: Natgun Construction Project No.: 95-0196
Concrete Supplier and Plant: RediMix Concrete - 12 1 Plant
Location of Placement: GEE Consultants, Inc. Laboratory Confirmation Cylinders
MAT E R I AL S s ...../ hatch Wts.
Description (Ibs./0.075 C.V> INS PECT I ON DATA
Mix Number: Wall slots Mix #689 Time Sample Batched: 3:20 pm
Cement: TXI Type I/II 799 Time Sampled: 3:45 pm
Sample Location: GEE Consultants, Inc.
Fly Ash: -0-- Truck/Ticket No: N/A
Coarse Aggregate: -0- Temperature:
Intermediate Aggregate: -0- Ambient Range: 87°F
Fine Aggregate: sand 2691 Concrete Range: 86°F
Slump Range (inches): 6~"
Admixtures: Weather Conditions: Partly Cloudy
1 Monex NW (C494(A)) 24 oz./yd. Time Started: Partly Cloudy
2 Monex Air 30 (C260) 6 oz/yd. Time Completed: N/A
3 Monex M150 (C494(F)) 112 oz./yd. Sample Air Content (%): 4V2%
Total Cubic Yards Placed: 0.06 C.Y.
Water: 36.9 gal. Required Strength (Lbs./sq.in.): 5,000
Specimen Measured Age Date Total Load Compressire Strength Remarks
Number Slump (in.) (Days) Tested (Lbs.) (Lbs./Sq.]n.)
CWT WS2 1 63A'' 3 10/02/95 144,700 5,120 Unit weight: 135.2 lbs/cu.ft.
CWT WS2 2 6a~'' 3 10/02/95 138,800 4,910
CWT WS2 3 6~" 3 10/06/95 137,340 4,860
CWT WS2 4 6~" 7 10/06/95 160,020 5,660
CWT WS2 5 6~" 28 10/27/95
CWT WS2 6 6~" 28 10/27/95
Test Methods Utilized Fracture Regular
ASTMC-31,C-39,C-143 (Unless Noted Otherwise) Cylinders Made By: w.l.
Remarks and/or Distribution:
cc: Mr. Larry Davis - City of Coppell
Mr. Bob Barbarisi, Jr. - Natgun Corporation
Mr. Gary Hendricks - ShimeL lacobs and Finklea
Mr. Gary Herron - RedilVlix Concrete
GMIi Consultants, Inc. Reviewed by:
All letters and reports are for the exclusive use of the client to whom they are addressed and shall not be reproduced without the full approval of GEE Consultants, Inc. The use of our name mast receive
our prior written approval. Our letters and reports apply only to the sample tested and/or inspected and are not necessarily indicative of the quantities of apparently identical or similar products.