Mansions Phase 1-LR 980528 (3) Rone Engineers, Inc. 1 4 Goodnight Lane Tel. (972) 241-451 '"~' RoneEn_q!ineer
Da~las,'Fort Worth Dallas, Texas Metro (972) 263-1555
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Pro!ect Mansions By The Lake Purchase Order
Number 3137-D7429-182 I Date of Observation 4128/98 Report Date 05,'28.,'98
I
To Western Rim Services
Location BUILDING SLAB 6, NORTHEAST CORER, 30' SOUTH, 5' WEST
Contractor
Supplier LATTIMORE Plant 7 Truck 460 Ticket 7050182
Time Sampled 8:10 Time Batched 8:00 Weather Condition CLOUDY
Concrete Temperature (CF) 70 Ambient Temperature (CF) 63 Mix Number 51
Mix Description 3000PSI W.,'R Unit Weignt Water Added 10 GALLONS
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 7.0
Concrete Cylinder Test(s)
Specimen Age I Test Date I Tota, ,_oa,:, I Compressive
No. (Days) (lbs.) Strength (psi) Strength Required (psi)
92A 7 5/05 92000 3250 3000/28 DAYS
B 28 5/26 131000 4630
C 28 5/26 1 20000 4240
D H
Curing Method Test Method I Standard 6" x 12" Engineer/Technician D. GODBEY
ASTM C31 ASTM C39I Area 28.27 sq. in.
Signature: Mike Fuller, (~ Supervisor, CMT
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Mike Hodge; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
L:MITATiONS. The test results presented herein vvefe prepared based bpon ~.he specific samples provided for testing. We assume no
resoonsibilit¥ for variation in qLlalit¥ (composition. appearance, performance, etc.i or any other feature of similar subject matter provided by
;)ersoos or conditions over which we nave no contrcl. Our letters a~cl reports are for the exclus;ve use of ;he clients to whom they are
[~ddressed.
c: wpwu; reports'D7429-182-98tST May 28, 1998