Mansions Phase 1-LR 980519 i Dallas/Eon Worth Dallas, Texas Metro (972) 263-1555 , 75229 Fax (972) 241-5174 Concrete Cylinder Test Report Project Mansion By The Lake Purchase Order Number 3137-D7429-105 I Date of Observation 3/24/98 Report Date 05/19/98 I To Western Rim Services Location BUILDING #29, SLAB, THE NORTHEAST CORNER, 5' WEST Contractor EDWARDS CONSTRUCTION Supplier LATTIMORE I Plant 6 ]Truck 803 Ticket 6068683 I I Time Sampled 7:20 Time Batched 7:00 Weather Condition CLEAR Concrete Temperature (°F) 67 Ambient Temperature (°F) 62 Mix Number 14 Mix Description 4.50 SACKS W/R Unit Weight Water Added NONE Physical Data ACTUAL SPECIFICATIONS SLUMP (in.) 5.0 Concrete Cylinder Test(s) Specimen Age Test Date No. (Days) (lbs.) Strength (psi) Strength Required (psi) 57A 7 3/31 56000 1980 3000/28 DAYS B 28 4/21 79000 2790* C 28 4/21 78000 2760* D 56 5/19 82000 2900* Curing Method Test Method J Standard 6" x 12" I Engineer/Technician D. GODBEY Area sq. ASTM C 31 I ASTM C 39,¢~ 28.27 in. I Signature: Mike Fuller, (/~ Supervisor, CMT Remarks and/or Distribution ~ *DIDN'T MEET REQUIRED STRENGTH Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Lee Stone; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:',wpwin\reports',D7429-105-98\ST May 19. 1998