Loading...
Mansions Phase 1-LR 980519 (5) Reno Engineers, Inc. ' 11~-~4 Goodnight Lane Tel. (972) 241-451'~- ineers Dallas.-'Fod Wortl~ Dallas, Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 Concrete Cylinder Test Report Project Mansions By The Lake Purchase Order Number 3137-D7429-174 I Date of Observation 4/21/98 Report Date 05/19/$8 I To Western Rim Services Location 10' EAST AND 2' SOUTH OFF NORTHEAST CORNER OF BUILDING #7 SLAB Contractor Supplier BUTLER I Plant 1 Truck 83 Ticket 018040 I Time Sampled 10:20 Time Batched 9:16 Weather Condition CLEAR Concrete Temperature (°F) 6:20 Ambient Temperature (°F) 6:00 Mix Number 304 Mix Description Unit Weight Water Added 20 GALLONS Physical Data ACTUAL SPECIFICATIONS SLUMP (in.) 6.75 Concrete Cylinder Test(s) Specimen Age Test Date No. (Days) (lbs.) Strength (psi) Strength Required (psi) 88A 7 4/28 65000 2300 3000/28 DAYS B 28 5/19 109000 3860 C 28 5/19 84000 2970* D 56 6/16 CuringMeth°d I TestMeth°d~ Standard 6" x12" I Engineer/TechnicianR'YARBROUGH ASTM C 31 ASTM C 39 Area 28.27 sq. in. Signature: Mike Fuller, ///fj Supervisor, CMT Remarks and/or Distribution~--.- CONTRACTOR CHANGED CONCRETE COMPANIES *DIDN'T MEET REQUIRED STRENGTH WILL TEST HOLD CYLINDER AT 56 DAY BREAK. Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hedge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality {composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:',wpwin\reports\D7429-174-98~ST May 19, 1998