Mansions Phase 1-LR 980515 Rone Engineers, Inc. 1'"'34 Goodnight Lane Tel. (972)241-45' RoneEnoineers
Dallas/Fort Wortln Dallas, Texas Metro (972) 263-1555
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansions By The Lake Purchase Order
Number 3137-D7429-154 Date of Observation 4/14/98 Report Date 05/15/98
To Western Rim Services
Location BUILDING //35 SLAB FROM SOUTHWEST CORNER GO 45' NORTH AND 6' EAST
Contractor
Supplier LATTIMORE I Plant 7 I Truck 574 Ticket 7049576
I
I
Time Sampled 7:10 Time Batched 7:00 Weather Condition CLEAR
Concrete Temperature (°F) 85 Ambient Temperature (°F) 69 Mix Number 51
Mix Description W/R Unit Weight Water Added NONE
Physical Data
ACT UAL S PEClFI CAT IO NS
SLUMP (in.) 8.0
Concrete Cylinder Test(s)
No. (Days) (lbs.) Strength (psi) Strength Required (psi)
82A 7 4/21 80000 2830 3000/28 DAYS
B 28 5/12 111000 3930
C 28 5/12 108000 3820
D H
ASTM C 31 ASTM C 39 Area 28.27 sq. in.
Signature: Mike Fuller,-~',/./ Supervisor, CMT
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Mike Hedge; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no
responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by
persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to 'whom [hey are
addressed.