Loading...
Mansions Phase 1-LR 980511 (02) 1~,4 ~_n~j~n44re, Inc. ~ ~ooclnioht Lane ' Tel. (972) 241-45. Dallas,'Fod Wortl~ Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 Concrete Cylinder Test Report. Project MANSIONS BY THE LAKE Purchase Order Number 3137-D7429-130 I Date of Observation 4/03/98 Report Date 05/11/98 To WESTERN RIM SERVICES Location BUILDING //37, SOUTHWEST CORNER Contractor Supplier LATTIMORE I Plant 7 Truck 572 Ticket 7049124 I Time Sampled 8:00 Time Bitched 6:30 Weather Condition CLEAR Concrete Temperature (°F) 71 Ambient Temperature (°F) 68 Mix Number 14 Mix Description 5.0 SACKS W/R Unit Weight Water Added 20 GALLONS Physical Data ACTUAL SPECIFICATIONS SLUMP (in.) 7.5 Concrete Cylinder Test(s) No. (Days) (lbs.) Strength (psi) Strength Required (psi) 73 7 4/10 81000 2870 3000/28 DAYS B 28 5/01 100000 3540 C 28 5/01 104000 3680 D H ! Curing Method Test Method Standard 6" x 12" I Engineer/Technician R. YARBROUGH ASTM C 31 I ASTM C 39~_~1 Area 28.27 sq. in. I Signature: Mike Fuller, (~_, Supervisor, CMT v Remarks and/or Distribution Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hedge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which 'we have no control. Our letters and repor[s are for the exclusive use of the clients to whom they are addressed. c:..wpwin;reports\D7429-130-98;ST May 11. 1998