Loading...
Mansions Phase 1-LR 980511 (03) {~Q.~ ~.~jin~er~, ~.~. C'L~'~4 ~oodnight Lane Te~. (~7~> ineers Dallas/Fort Worth Dallas, Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 Concrete Cylinder Test Report Project MANSIONS BY THE LAKE Purchase Order Number 3137-D7429-131 I Date of Observation 4/03/98 Report Date 05/11/98 To WESTERN RIM SERVICES Location TIE IN NORTH OF BUILDING #35, NORTHWEST CORNER SLAB Contractor EDWARDS CONCRETE Supplier LATTIMORE I Plant 7 I Truck 572 Ticket 7049138 I I Time Sampled 8;45 Time Batched 8:02 Weather Condition CLEAR Concrete Temperature (°F) 72_ Ambient Temperature (°F) 70 Mix Number 14 Mix Description 4.50 SACKS W/R Unit Weight Water Added 30 GALLONS Physical Data ACTUAL SPECIFICATIONS SLUMP (in.) 8.0 Concrete Cylinder Test(s) Specimen Age Test Date No. (Days) (lbs.) Strength (psi) Strength Required (psi) 74A 7 4/10 63500 2250 3000/28 DAYS B 28 5/01 84000 2970* C 28 5/01 85000 3010 D 56 5/29 ASTM C 31 ASTM C 39 Area 28.27 sq. in. Signature: Mike Fuller,//'~upervisor, CMT Remarks and/or Distribution- *DIDN'T MEET REQUIRED STRENGTH, WILL TEST HOLD CYLINDER AT 56 DAY BREAK. Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:'.wpwint, repor~s\D7429-131-98\ST May 11. 1998